儿童患者CT引导下引流管置入相关的辐射剂量
本研究回顾性分析了2008年1月至2013年12月在本机构接受CT引导下引流管置入的52例儿童患者(平均年龄11.0岁),量化了置管及随访评估相关的辐射剂量。结果显示,所有置管及随访检查的平均有效剂量为5.3 mSv(范围0.7-17.1),62%(32/52)的患儿有效剂量低于5 mSv。作者认为多数患儿接受的总辐射剂量与诊断性检查范围相当,该信息可用于向家长和提供者说明CT引导下引流管置入时的辐射剂量。
要点
- 儿童CT引导下引流管置入及随访的平均有效剂量为5.3 mSv(范围0.7-17.1)。
- 62%(32/52)的患儿总有效剂量低于5 mSv。
- 术前诊断性CT的平均有效剂量为7.3 mSv(范围1.1-25.5)。
核心结论
- 本机构多数接受CT引导下引流管置入的儿童患者所接受的总辐射剂量与诊断性检查范围相当。
研究设计与样本
- 回顾性研究,通过电子病历和PACS检索2008年1月至2013年12月在本机构进行的儿童(<18岁)CT引导下引流管置入,共识别52例引流操作,平均年龄11.0岁(5周至17岁);将剂量长度乘积、透视时间和采集次数通过蒙特卡洛模拟及基于年度质量控制测试的年龄适用转换因子转换为有效剂量。
诊断标准与关键数值
- 所有引流操作及随访检查的平均有效剂量为5.3 mSv(范围0.7-17.1)。
- 62%(32/52)的儿童有效剂量低于5 mSv。
- 47例患者进行了诊断性CT,平均有效剂量为7.3 mSv(范围1.1-25.5)。
- 引流管留置平均16.9天(范围0-75天),随访期间平均每人0.9次(0-5次)窦道造影。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: To date, there are limited radiation dose data on CT-guided procedures in pediatric patients.
OBJECTIVE: Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose.
MATERIALS AND METHODS: We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing.
RESULTS: Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv.
CONCLUSION: The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary.
引用
- Schwartz CJ, Isaacson AJ, Fordham LA, et al. Radiation dose associated with CT-guided drain placement for pediatric patients. Pediatr Radiol. 2017. PMID: 28283724. doi:10.1007/s00247-017-3814-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。