基于模型的迭代重建在颈动脉CT血管成像中减少牙科硬件金属伪影的效用评估
纳入37例有牙科硬件的颈动脉CTA患者,比较FBP、ASIR和MBIR三种重建方法的金属伪影指数及两名神经放射科医生的五分法视觉评分。MBIR的伪影指数较FBP和ASIR均显著改善(p<0.001),视觉评分也显著优于两者(p<0.001);FBP与ASIR间伪影指数无显著差异(p=0.502),视觉评分相同。
要点
- MBIR可显著降低牙科硬件所致金属伪影,伪影指数较FBP和ASIR均改善(p<0.001)。
- FBP与ASIR间伪影指数无显著差异(p=0.502),视觉评分相同。
- MBIR的视觉评分显著优于FBP和ASIR(p<0.001),观察者间一致性良好(kappa 0.747-0.778)。
核心结论
- 在颈动脉CTA中,MBIR较FBP和ASIR显著减少牙科硬件金属伪影,视觉评分也显著更优;FBP与ASIR间伪影指数无显著差异。
研究设计与样本
- 纳入37例有牙科硬件并接受颈动脉CTA的患者,使用GE Discovery CT750 HD扫描仪,分别以FBP、ASIR和MBIR重建;由两名神经放射科医生对轴位和矢状位重建图像进行五分法视觉评估,采用加权kappa分析观察者间一致性。
关键影像表现/征象
- 测量受牙科金属伪影影响最重的颈内动脉颈段标准差(SD1)及未受伪影影响的颈总动脉标准差(SD2),计算伪影指数AI=[(SD1)²-(SD2)²]^1/2。
- MBIR的伪影指数较FBP和ASIR均显著改善(p<0.001)。
- FBP与ASIR间伪影指数无显著差异(p=0.502)。
诊断标准与关键数值
- 伪影指数AI计算公式:AI=[(SD1)²-(SD2)²]^1/2,其中SD1为受牙科金属伪影影响最重的颈内动脉颈段标准差,SD2为未受伪影影响的颈总动脉标准差。
- 视觉评估采用五分法,对轴位及矢状位重建图像分别评分。
- MBIR视觉评分显著优于FBP和ASIR(p<0.001),ASIR与FBP评分相同。
临床应用与阅片要点
- 对有牙科硬件的患者行颈动脉CTA时,MBIR较FBP和ASIR可减少金属伪影并改善颈内动脉的视觉评估。
- FBP与ASIR在减少牙科金属伪影方面无显著差异。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this study is to assess the value of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) for reduction of metal artifacts due to dental hardware in carotid CT angiography (CTA).
METHODS: Thirty-seven patients with dental hardware who underwent carotid CTA were included. CTA was performed with a GE Discovery CT750 HD scanner and reconstructed with filtered back projection (FBP), ASIR, and MBIR. We measured the standard deviation at the cervical segment of the internal carotid artery that was affected most by dental metal artifacts (SD1) and the standard deviation at the common carotid artery that was not affected by the artifact (SD2). We calculated the artifact index (AI) as follows: AI = [(SD1)2 - (SD2)2]1/2 and compared each AI for FBP, ASIR, and MBIR. Visual assessment of the internal carotid artery was also performed by two neuroradiologists using a five-point scale for each axial and reconstructed sagittal image. The inter-observer agreement was analyzed using weighted kappa analysis.
RESULTS: MBIR significantly improved AI compared with FBP and ASIR (p < 0.001, each). We found no significant difference in AI between FBP and ASIR (p = 0.502). The visual score of MBIR was significantly better than those of FBP and ASIR (p < 0.001, each), whereas the scores of ASIR were the same as those of FBP. Kappa values indicated good inter-observer agreements in all reconstructed images (0.747-0.778).
CONCLUSIONS: MBIR resulted in a significant reduction in artifact from dental hardware in carotid CTA.
引用
- Kuya K, Shinohara Y, Kato A, et al. Reduction of metal artifacts due to dental hardware in computed tomography angiography: assessment of the utility of model-based iterative reconstruction. Neuroradiology. 2017. PMID: 28255903. doi:10.1007/s00234-017-1811-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。