识别颈动脉狭窄患者中细微的近闭塞:一项计算机断层血管造影研究
该研究分析了467例拟行内膜切除术的中重度颈动脉狭窄患者的颈动脉CTA,采用双侧远端颈内动脉管径差1.0 mm作为标准识别近闭塞。结果发现126例近闭塞,同侧管径差均值1.8 mm(95%CI 1.6-1.9),标准差0.8 mm;未满足标准者中140例中度狭窄、93例重度狭窄。结论认为1.0 mm阈值可提高CTA对细微近闭塞的检出。
要点
- 双侧远端颈内动脉管径差1.0 mm可作为CTA识别近闭塞的实用阈值。
- 该阈值下近闭塞发生率较高,需注意避免低估狭窄程度。
- 即使远端管径缩小不明显,也应测量双侧管径差以识别细微近闭塞。
核心结论
- 采用1.0 mm的同侧远端颈内动脉管径差阈值识别动脉粥样硬化性近闭塞可导致相对较高的近闭塞发生率;CTA中1.0 mm鉴别阈值可作为实用工具提高细微近闭塞的检出。
研究设计与样本
- 研究分析了467例拟行内膜切除术的中重度颈动脉狭窄患者的颈动脉CTA,从薄层轴位原始图像测量双侧远端颈内动脉管径,采用基于既往研究的1.0 mm个体内双侧管径差标准识别近闭塞,分析时排除影响管径测量的显著颈动脉病变病例。
诊断标准与关键数值
- 以双侧远端颈内动脉管径差1.0 mm作为近闭塞判断标准;126例满足同侧近闭塞标准,管径差均值1.8 mm(95%CI 1.6-1.9),标准差0.8 mm;未满足标准者中140例为中度狭窄(50-69%)、93例为重度狭窄(70-99%)。
临床应用与阅片要点
- 在CTA阅片时测量双侧远端颈内动脉管径差,采用1.0 mm阈值有助于识别即使远端管径缩小不明显的细微近闭塞,避免低估狭窄程度。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Near-occlusion of the internal carotid artery (ICA) is a significant luminal diameter (LD) reduction beyond a tight atherosclerotic carotid stenosis (CS). Recognition of even subtle near-occlusions is essential to prevent underestimation of the stenosis degree. Our goal was to investigate the prevalence of near-occlusion among CS patients using a single standard criterion to facilitate its recognition, even when distal ICA LD reduction is not visually evident in computed tomography angiography (CTA).
METHODS: We analysed carotid artery CTAs of 467 patients with moderate-to-severe CS scheduled for endarterectomy. We performed measurements of the bilateral distal ICA LDs from thin axial source images and utilized a 1.0 mm intra-individual side-to-side distal ICA LD difference to distinguish near-occlusions, based on a previous study, aware of the vagaries of measurement. For analysis stratification, we excluded cases with significant carotid pathology affecting LD measurements.
RESULTS: We discovered 126 near-occlusions fulfilling our criterion of ipsilateral near-occlusion: the mean LD side-to-side difference (mm) with 95% confidence interval being 1.8 (1.6, 1.9) and a standard deviation of 0.8 mm. Among the 233 cases not meeting our near-occlusion criterion, we found 140 moderate (50-69%) and 93 severe (70-99%) ipsilateral stenoses.
CONCLUSION: The utilization of 1.0 mm cut-off value for the intra-individual distal ICA LD side-to-side difference to distinguish atherosclerotic ICA near-occlusion leads to a relatively high incidence of near-occlusion. In CTA, recently suggested to be used for near-occlusion diagnosis, a discriminatory 1.0 mm cut-off value could function as a pragmatic tool to enhance the detection of even subtle near-occlusions.
引用
- Koskinen SM, Silvennoinen H, Ijäs P, et al. Recognizing subtle near-occlusion in carotid stenosis patients: a computed tomography angiographic study. Neuroradiology. 2017. PMID: 28251333. doi:10.1007/s00234-017-1791-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。