文献速递骨肌神经MR

椎体局灶性骨髓病变的体素内不相干运动扩散加权磁共振成像:鉴别结节性增生性造血骨髓与恶性病变的初步经验

Intravoxel incoherent motion diffusion-weighted magnetic resonance imaging of focal vertebral bone marrow lesions: initial experience of the differentiation of nodular hyperplastic hematopoietic bone marrow from malignant lesions.
PubMed 文献 · Skeletal Radiol · 2017-03-06

回顾性分析33例患者58个椎体骨髓病变(9个结节性增生性造血骨髓、39个骨转移、10个骨髓瘤),采用3.0-T磁共振仪行11个b值的IVIM扩散加权成像,计算ADC、D、f、D*值。结节性增生性造血骨髓的ADC和D值显著低于恶性病变,f值显著高于恶性病变,D*值无显著差异;D值的AUC为1.000,显著大于ADC的AUC(0.902)。

要点

  • 结节性增生性造血骨髓的ADC和D值显著低于恶性椎体骨髓病变,f值显著高于恶性病变。
  • D值的AUC为1.000,显著大于ADC的AUC(0.902),鉴别诊断性能优于ADC、f和D*。
  • D*值在结节性增生性造血骨髓与恶性病变间无显著差异(p=0.688)。

核心结论

  • 体素内不相干运动扩散加权磁共振成像可用于鉴别结节性增生性造血骨髓与恶性椎体骨髓病变;结节性增生性造血骨髓的D值显著更低,且D值在该鉴别中的诊断性能优于ADC、f和D*值。

研究设计与样本

  • 回顾性研究,共纳入33例患者58个椎体骨髓病变(9个结节性增生性造血骨髓、39个骨转移、10个骨髓瘤),所有诊断经病理或影像评估确认;采用3.0-T磁共振仪行11个b值(0至800 s/mm2)的IVIM扩散加权成像,计算ADC、D、f和D*值;ADC与IVIM参数采用Mann-Whitney U检验比较,采用ROC曲线分析评估ADC、D、f和D*对椎体骨髓病变鉴别的诊断性能,并评估形态学MR序列的诊断性能作为对照。

诊断标准与关键数值

  • 结节性增生性造血骨髓的ADC和D值均显著低于恶性椎体骨髓病变(两者p值均<0.001)。
  • 结节性增生性造血骨髓的f值显著高于恶性椎体骨髓病变(p<0.001)。
  • D*值在结节性增生性造血骨髓与恶性椎体骨髓病变间无显著差异(p=0.688)。
  • ROC分析中D值的AUC为1.000,显著大于ADC的AUC(0.902)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the ability of intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (MRI) parameters to differentiate nodular hyperplastic hematopoietic bone marrow (HHBM) from malignant vertebral bone marrow lesions (VBMLs).

MATERIALS AND METHODS: A total of 33 patients with 58 VBMLs, including 9 nodular HHBM lesions, 39 bone metastases, and 10 myelomas, were retrospectively assessed. All diagnoses were confirmed either pathologically or via image assessment. IVIM diffusion-weighted MRI with 11 b values (from 0 to 800 s/mm2) were obtained using a 3.0-T MR imager. The apparent diffusion coefficient (ADC), pure diffusion coefficient (D), perfusion fraction (f), and pseudodiffusion coefficient (D*) were calculated. ADC and IVIM parameters were compared using the Mann-Whitney U test. Receiver operating characteristic (ROC) curve analysis was performed to assess the diagnostic performances of ADC, D, f, and D* in terms of VBML characterization. The diagnostic performance of morphological MR sequences was also assessed for comparison.

RESULTS: The ADC and D values of nodular HHBM were significantly lower than those of malignant VBML (both p values < 0.001), whereas the f value was significantly higher (p < 0.001). However, there were no significant differences in D* between the two groups (p = 0.688). On ROC analysis, the area under the curve (AUC) for D was 1.000, which was significantly larger than that for ADC (AUC = 0.902).

CONCLUSION: Intravoxel incoherent motion diffusion-weighted MRI can be used to differentiate between nodular HHBM and malignant VBML. The D value was significantly lower for nodular HHBM, and afforded a better diagnostic performance than the ADC, f, and D* values in terms of such differentiation.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Park S, Kwack KS, Chung NS, et al. Intravoxel incoherent motion diffusion-weighted magnetic resonance imaging of focal vertebral bone marrow lesions: initial experience of the differentiation of nodular hyperplastic hematopoietic bone marrow from malignant lesions. Skeletal Radiol. 2017. PMID: 28265697. doi:10.1007/s00256-017-2603-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。