文献速递骨肌MR

膝关节内部紊乱的诊断:脂肪抑制与非脂肪抑制容积各向同性涡轮自旋回波采集MRI的比较

Diagnosis of Internal Derangement of the Knee: Volume Isotropic Turbo Spin-Echo Acquisition MRI With Fat Suppression Versus Without Fat Suppression.
PubMed 文献 · AJR Am J Roentgenol · 2017-03-16

本研究回顾性比较了伴与不伴脂肪抑制的3D容积各向同性涡轮自旋回波采集(VISTA)MRI在评估膝关节韧带、半月板和软骨撕裂中的价值,以关节镜手术所见为参考标准。结果显示,不伴脂肪抑制的VISTA在内侧半月板撕裂(特异度95.0% vs 81.3%,准确率94.4% vs 85.9%)和软骨缺损(特异度99.1% vs 96.8%)的特异度上均显著高于脂肪抑制VISTA,其余指标无显著差异。

要点

  • 不伴脂肪抑制的VISTA对内侧半月板撕裂的特异度(95.0%)和准确率(94.4%)显著高于脂肪抑制VISTA(81.3%和85.9%)。
  • 不伴脂肪抑制的VISTA对软骨缺损的特异度(99.1%)显著高于脂肪抑制VISTA(96.8%)。
  • 其余韧带和半月板撕裂评估中两种方法无显著差异。

核心结论

  • 3D VISTA MRI在评估内侧半月板撕裂和软骨缺损时,特异度高于脂肪抑制VISTA。

研究设计与样本

  • 回顾性研究,由两名放射科医生独立回顾性分析71例MRI检查,每例均包含伴和不伴脂肪抑制的3D中间加权VISTA图像,以关节镜手术所见为标准参考。

诊断标准与关键数值

  • 内侧半月板撕裂:VISTA特异度95.0%、准确率94.4%;脂肪抑制VISTA特异度81.3%、准确率85.9%(特异度p=0.003,准确率p=0.004)。
  • 软骨缺损:VISTA特异度99.1%;脂肪抑制VISTA特异度96.8%(p=0.039)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to compare 3D volume isotropic turbo spin-echo acquisition (VISTA) MRI with and without fat suppression for use in evaluating ligaments, menisci, and cartilage.

MATERIALS AND METHODS: Two radiologists retrospectively and independently reviewed 71 MRI studies. Each study consisted of 3D intermediate-weighted VISTA images with fat suppression and without fat suppression. The presence of tears of the anterior cruciate and posterior cruciate ligaments, tears of the medial and lateral menisci, and cartilaginous defects was evaluated. Arthroscopic surgical findings were used as the standard of reference. Statistical analysis was performed to calculate the sensitivity, specificity, and accuracy of the two methods.

RESULTS: Mean specificity and accuracy for medial meniscal tears were significantly higher with VISTA (specificity, 95.0%; accuracy, 94.4%) than with fat-suppressed VISTA (FS-VISTA) (specificity, 81.3%; accuracy, 85.9%), and the difference was statistically significant (specificity, p = 0.003; accuracy, p = 0.004). Mean specificity for cartilaginous defects was also significantly higher with VISTA than with FS-VISTA (99.1% vs 96.8%, p = 0.039). There were no other significant differences between the two methods.

CONCLUSION: Three-dimensional VISTA MRI has higher specificity than FS-VISTA imaging for evaluation of medial meniscal tears and cartilaginous defects.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Lee JH, Yoon YC, Park KJ, et al. Diagnosis of Internal Derangement of the Knee: Volume Isotropic Turbo Spin-Echo Acquisition MRI With Fat Suppression Versus Without Fat Suppression. AJR Am J Roentgenol. 2017. PMID: 28301221. doi:10.2214/AJR.16.17217

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。