MRI上髌股关节对线测量的变异性:膝关节位置的影响
本研究对10名男性、2名女性健康志愿者的12个膝关节在四种不同体位下进行限制性MRI,测量TT-TG、PT-TG、TT-PCL和PT-PCL距离。结果显示TT-TG和PT-TG在不同膝关节位置间变异较大,而TT-PCL和PT-PCL受膝关节位置影响不显著,变异性显著更小。
要点
- TT-PCL和PT-PCL测量受膝关节位置影响不显著,变异性显著小于TT-TG和PT-TG。
- TT-TG在15°屈曲时平均11.4 mm,较休息位18.1 mm明显减小,ICC仅0.539。
- PT-TG在30°屈曲时平均11.8 mm,较休息位18.1 mm明显减小,ICC为0.633。
核心结论
- 在MRI上,无论膝关节位置如何,TT-PCL和PT-PCL测量的变异性显著小于TT-TG和PT-TG测量;尽管需要进一步研究,TT-PCL和PT-PCL测量可能提供更可靠的胫骨结节外移和髌股关节对线评估。
研究设计与样本
- 对12个健康志愿者膝关节(10男2女,平均年龄28岁)在四种不同体位下进行限制性MRI的前瞻性影像学研究;以TT、TG、PT、PCL四个解剖标志点测量距离。
诊断标准与关键数值
- TT-TG平均±SD:休息位18.1±7.9 mm,完全伸直位17.3±5.3 mm,15°屈曲位11.4±5.7 mm,30°屈曲位11.7±6.0 mm,ICC=0.539。
- PT-TG平均±SD:休息位18.1±6.3 mm,完全伸直位17.9±4.7 mm,15°屈曲位13.2±5.2 mm,30°屈曲位11.8±4.3 mm,ICC=0.633。
- TT-PCL平均±SD:休息位23.5±6.8 mm,完全伸直位20.5±5.5 mm,15°屈曲位22.8±6.2 mm,30°屈曲位22.8±6.7 mm,ICC=0.484。
- PT-PCL平均±SD:休息位23.4±5.3 mm,完全伸直位21.5±4.5 mm,15°屈曲位22.3±4.3 mm,30°屈曲位23.1±4.8 mm,ICC=0.509。
- 膝关节位置对TT-PCL和PT-PCL距离无显著影响。
临床应用与阅片要点
- 作者认为TT-PCL和PT-PCL测量可能提供更可靠的胫骨结节外移和髌股关节对线评估。
局限性
- 原文结论指出尽管需要进一步研究(further studies are warranted)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study was to determine the variability of distances between four distinct anatomic landmarks used for the evaluation of patellofemoral alignment while implementing controlled changes in patient positioning during MRI.
MATERIALS AND METHODS: Limited MRI was performed of 12 knees in healthy volunteers (10 men, two women; mean age, 28 years) with the knees in four different positions. The four landmarks used were TT (the most anterior point of the osseous tibial tubercle), TG (the nadir of the cartilaginous trochlear groove), PT (the center of the patellar tendon insertion on the tibia), and PCL (the medial border of the posterior cruciate ligament at its insertion along the posterior tibia). TT-TG, PT-TG, TT-PCL, and PT-PCL distances were measured on the MR images. Each distance was measured with the knee at maximum patient comfort (rest), full extension, 15° of flexion, and 30° of flexion. Linear mixed models with random intercepts were implemented to determine variability between measurements and knee position.
RESULTS: In general, measurements based on anatomic landmark and knee position varied greatly. The greatest variability in different knee positions was seen in mean TT-TG and PT-TG distances ± SD (TT-TG: rest, 18.1 ± 7.9 mm; full extension, 17.3 ± 5.3 mm; 15° of flexion, 11.4 ± 5.7 mm; 30° of flexion, 11.7 ± 6.0 mm; intraclass correlation coefficient [ICC] = 0.539; PT-TG: rest, 18.1 ± 6.3 mm; full extension, 17.9 ± 4.7 mm; 15° of flexion, 13.2 ± 5.2 mm; 30° of flexion, 11.8 ± 4.3 mm; ICC = 0.633). In contrast, knee position did not significantly affect distances for TT-PCL and PT-PCL (TT-PCL: rest, 23.5 ± 6.8 mm; full extension, 20.5 ± 5.5 mm; 15° of flexion, 22.8 ± 6.2 mm; 30° of flexion, 22.8 ± 6.7 mm; ICC = 0.484; PTPCL: rest, 23.4 ± 5.3 mm; full extension, 21.5 ± 4.5 mm; 15° of flexion, 22.3 ± 4.3 mm; 30° of flexion, 23.1 ± 4.8 mm; ICC = 0.509).
CONCLUSION: On MRI, TT-PCL and PT-PCL measurements have significantly less variability compared with TT-TG and PT-TG measurements, regardless of knee position. Although further studies are warranted, the use of TT-PCL and PT-PCL measurements may offer more reliable assessment of tibial tubercle lateralization and patellofemoral alignment.
引用
- Marquez-Lara A, Andersen J, Lenchik L, et al. Variability in Patellofemoral Alignment Measurements on MRI: Influence of Knee Position. AJR Am J Roentgenol. 2017. PMID: 28267362. doi:10.2214/AJR.16.17007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。