文献速递骨肌US

类风湿关节炎伸肌腱异常的超声特征及其与关节疾病活动性的关系:一项初步研究

Sonographic Characteristics of Extensor Tendon Abnormalities and Relationship With Joint Disease Activity in Rheumatoid Arthritis: A Pilot Study.
PubMed 文献 · J Ultrasound Med · 2017-03-04

回顾性横断面研究纳入26例类风湿关节炎患者,对41只手205个关节行B型和能量多普勒关节活动度评分,并检查伸肌腱B型改变及能量多普勒信号;腱周无回声积液和腱周能量多普勒信号分别见于41%和39%的肌腱,二者与严重滑膜炎相关(共同OR分别为3.52和2.52)。

要点

  • 类风湿关节炎患者手背伸肌腱可出现腱周无回声积液、腱周低回声组织、腱周能量多普勒信号及肌腱增厚。
  • 腱周无回声积液与严重滑膜炎相关,共同OR为3.52(95%CI 1.45-8.53)。
  • 腱周能量多普勒信号与严重滑膜炎相关,共同OR为2.52(95%CI 1.13-5.63)。

核心结论

  • 背侧伸肌腱的异常表现包括腱周无回声积液、腱周低回声组织、腱周能量多普勒信号和肌腱增厚;存在腱周无回声积液和能量多普勒信号的患者,其关节B型和能量多普勒评分显示的疾病活动性更严重。

研究设计与样本

  • 回顾性横断面研究,纳入26例接受手部超声检查的类风湿关节炎患者,共回顾41只手和205个关节;采用B型和能量多普勒对关节活动性评分,并检查伸肌腱的B型改变和能量多普勒信号。

关键影像表现/征象

  • 伸肌腱B型改变包括腱周无回声积液、腱周低回声组织、腱周组织及肌腱增厚。
  • 腱周无回声积液见于41%的肌腱,腱周能量多普勒信号见于39%的肌腱。
  • 44%和28%的患者B型和能量多普勒评分分别位于上三分位。

诊断标准与关键数值

  • B型和能量多普勒评分均分为3类或三分位:0至0.9、1至1.9和2至3。
  • 腱周无回声积液与严重滑膜炎的共同OR为3.52(95%CI 1.45-8.53)。
  • 腱周能量多普勒信号与严重滑膜炎的共同OR为2.52(95%CI 1.13-5.63)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To characterize abnormalities in the dorsal extensor tendons of the hand and determine the importance of these findings in rheumatoid arthritis.

METHODS: A retrospective cross-sectional study was done on 26 patients with rheumatoid arthritis who had sonography of their hands. B-mode and power Doppler joint activity were scored, and the extensor tendons were examined for B-mode changes and power Doppler signals. B-mode changes included anechoic fluid around tendons, hypoechoic tissue around tendons, paratendon tissue and tendon thickening, as well as vascularity around the tendon, for which peritendon power Doppler signals were recorded.

RESULTS: Forty-one hands and 205 joints were reviewed. Anechoic fluid around the tendons and peritendon power Doppler signals were observed in 41% and 39%, respectively; 44% and 28% of patients had B-mode and power Doppler scores in the upper tertile, respectively. For both B-mode and power Doppler scores, 3 categories or tertiles were created, 0 to 0.9, 1 to 1.9, and 2 to 3. We reported the percentage of patients with power Doppler and B-mode scores in this category. The severity of synovitis was associated with anechoic fluid around the tendons and peritendon power Doppler signals according to the Cochran-Mantel-Haenszel test. The common odds ratio was 3.52 (95% confidence interval, 1.45- 8.53) for anechoic fluid around the tendons and severe synovitis. The common odds ratio was 2.52 (95% confidence interval, 1.13-5.63) for peritendon power Doppler signals and severe synovitis.

CONCLUSIONS: Findings at the dorsal extensor tendons were anechoic fluid around tendons, hypoechoic tissue around tendons, peritendon power Doppler signals, and tendon thickening. Patients with anechoic fluid and power Doppler signals were found to have more severe disease activity at the joints based on B-mode and power Doppler scores.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ramrattan LA, Kaeley GS. Sonographic Characteristics of Extensor Tendon Abnormalities and Relationship With Joint Disease Activity in Rheumatoid Arthritis: A Pilot Study. J Ultrasound Med. 2017. PMID: 28258622. doi:10.7863/ultra.16.05024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。