文献速递儿科影像骨肌US

手部指骨定量超声测量未揭示支气管哮喘患儿的骨骼异常:一项纵向观察

Quantitative Ultrasound Measurement at the Hand Phalanges Does Not Reveal Skeletal Disturbances in Children With Bronchial Asthma: A Longitudinal Observation.
PubMed 文献 · J Ultrasound Med · 2017-03-04

这项前瞻性纵向观察对34例接受吸入糖皮质激素治疗的哮喘患儿进行手部指骨定量超声测量,基线及平均2.35±0.20年后各测一次,并与年龄、性别、体型匹配的健康对照比较。结果显示患儿振幅依赖声速(Ad-SoS)及其Z评分与健康对照无显著差异,随访期间无人出现Ad-SoS显著下降。

要点

  • 哮喘患儿基线Ad-SoS均值1940.5±49.6 m/s、Z评分-0.26±0.80,与健康对照无显著差异。
  • 随访时Ad-SoS均值1976.2±63.6 m/s、Z评分-0.18±1.16,与健康对照仍无显著差异。
  • 随访期间18例Ad-SoS显著升高(超过最小显著变化阈值),16例无显著变化,无人显著下降。

核心结论

  • 手部指骨定量超声作为诊断工具,未发现接受吸入糖皮质激素治疗的哮喘患儿与健康对照在骨骼发育模式上存在本质差异。

研究设计与样本

  • 前瞻性纵向观察研究,纳入34例哮喘患儿,在基线和平均2.35±0.20年后进行手部指骨定量超声测量,并与从既往健康儿童数据库中选择的年龄、性别、体型匹配对照比较。

关键影像表现/征象

  • 手部指骨定量超声测量获得振幅依赖声速(Ad-SoS),用于评估骨骼状态。
  • 哮喘患儿基线Ad-SoS均值1940.5±49.6 m/s,Z评分均值-0.26±0.80。
  • 随访时Ad-SoS均值1976.2±63.6 m/s,Z评分均值-0.18±1.16。
  • 上述定量超声结果与健康对照相比均无显著差异。

诊断标准与关键数值

  • 以振幅依赖声速(Ad-SoS)为定量超声参数,单位m/s,并计算Z评分。
  • 个体Ad-SoS变化以最小显著变化阈值为判定标准:18例显著升高,16例无显著变化,0例显著下降。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the skeletal status in asthmatic children treated with inhaled corticosteroids in a longitudinal observation by quantitative ultrasound (US) measurement at the hand phalanges.

METHODS: Thirty-four children were studied prospectively. Quantitative US measurements were performed at baseline and after a mean ± SD of 2.35 ± 0.20 years. The obtained results were compared to age-, sex-, and body size-matched control participants selected from a database of previously examined healthy children. Individual changes in the amplitude-dependent speed of sound (Ad-SoS) during the follow-up period were also analyzed.

RESULTS: The mean age of the asthmatic children was 10.6 ± 2.5 years. The mean Ad-SoS in the asthmatic children at baseline was 1940.5 ± 49.6 m/s, and the mean Z score was -0.26 ± 0.80. Corresponding values at the follow-up examination were 1976.2 ± 63.6 m/s and -0.18 ± 1.16. The results did not differ significantly in comparison to the healthy controls. The analysis of individual changes in Ad-SoS revealed that 18 participants had a significant increase in this parameter (ie, exceeding the least significant change threshold), and 16 did not have a significant change in their values. No one had a significant decrease in Ad-SoS.

CONCLUSIONS: Quantitative US at the hand phalanges applied as a diagnostic tool revealed no essential differences in the pattern of skeletal development between asthmatic children treated with inhaled glucocorticosteroids and healthy controls.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Adamczyk P, Pluskiewicz W, Halaba Z, et al. Quantitative Ultrasound Measurement at the Hand Phalanges Does Not Reveal Skeletal Disturbances in Children With Bronchial Asthma: A Longitudinal Observation. J Ultrasound Med. 2017. PMID: 28258615. doi:10.7863/ultra.16.01017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。