文献速递乳腺USMR

自动乳腺容积扫描(ABVS)与手持超声的诊断性能比较:以乳腺MRI为金标准

Diagnostic Performance of Automated Breast Volume Scanning (ABVS) Compared to Handheld Ultrasonography With Breast MRI as the Gold Standard.
PubMed 文献 · Acad Radiol · 2017-03-20

本研究以乳腺MRI为金标准,对28例患者39侧含至少一个MRI可见病灶的乳腺行手持超声(HHUS)与自动乳腺容积扫描(ABVS),比较病灶检出、定位、最大径及BI-RADS分类。ABVS检出59个病灶、HHUS检出54个,MRI检出72个;两者敏感度、特异度、诊断准确率、阳性预测值、阴性预测值均无显著差异。作者结论认为ABVS可作为HHUS的替代方法,但评估腋窝淋巴结受限且缺乏多普勒或弹性成像能力。

要点

  • ABVS与HHUS在敏感度、特异度、诊断准确率、阳性预测值、阴性预测值上均无显著差异。
  • ABVS与MRI同象限定位一致率94.3%,HHUS与MRI为91.2%。
  • ABVS-MRI病灶大小测量相关系数r=0.89,略高于HHUS-MRI的r=0.82(P<.001)。

核心结论

  • ABVS可作为HHUS的替代方法,具有操作者独立性及更好可重复性的优势,但评估腋窝淋巴结受限且缺乏多普勒或弹性成像能力,而这些在HHUS中有时提供重要补充信息。

研究设计与样本

  • 研究纳入28例患者共39侧在乳腺MRI上至少可见一个病灶的乳腺,均行HHUS与ABVS检查;以乳腺MRI为金标准,并在可获得时(21例)与组织学诊断比较。

关键影像表现/征象

  • MRI检出72个病灶,ABVS检出59个病灶,HHUS检出54个病灶。
  • 组织病理学证实恶性15例。
  • ABVS与MRI同象限定位一致率为94.3%,HHUS与MRI为91.2%。
  • 与MRI病灶大小比较(±3 mm)判读正确者HHUS为79.4%、ABVS为80%。
  • ABVS-MRI大小测量相关系数r=0.89,HHUS-MRI为r=0.82,P<.001。

诊断标准与关键数值

  • ABVS敏感度93.3%、特异度83.3%、诊断准确率87.2%、阳性预测值77.8%、阴性预测值95.2%。
  • HHUS敏感度100%、特异度83.3%、诊断准确率89.7%、阳性预测值78.9%、阴性预测值100%。
  • ABVS与HHUS在上述各项诊断性能指标上均无显著差异。

临床应用与阅片要点

  • 作者结论认为ABVS可作为HHUS的替代方法,其优势为操作者独立性和更好可重复性。
  • 作者指出ABVS在评估腋窝淋巴结方面受限,且缺乏多普勒或弹性成像能力,而这些在HHUS中有时提供重要补充信息。

局限性

  • ABVS在评估腋窝淋巴结方面受限。
  • ABVS缺乏多普勒或弹性成像能力,而这些在HHUS中有时提供重要补充信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study aimed to compare the diagnostic value of automated breast volume scanning (ABVS) to that of handheld ultrasonography (HHUS) using breast magnetic resonance imaging (MRI) as the gold standard.

MATERIALS AND METHODS: Twenty-eight patients with 39 examined breasts with at least one lesion visible in breast MRI underwent HHUS and ABVS. Detection rate, localization, maximum diameter, and Breast Imaging Reporting and Data System classification were compared. Sensitivity, specificity, diagnostic accuracy, positive predictive value, and negative predictive value were calculated for HHUS and ABVS. Lesion localization and maximum diameters based on HHUS and ABVS were compared to size measurement in MRI. Breast Imaging Reporting and Data System categories based on each method were compared to the MRI diagnosis (malignant or benign) or, if available (21 cases), with the histologic diagnosis.

RESULTS: MRI detected 72 lesions, ABVS 59 lesions, and HHUS 54 lesions. Malignancy was proven histopathologically in 15 cases. There was no significant difference between ABVS and HHUS in terms of sensitivity (93.3% vs. 100%), specificity (83.3% vs. 83.3%), diagnostic accuracy (87.2% vs. 89.7%), positive predictive value (77.8% vs. 78.9%), and negative predictive value (95.2% vs. 100%). Agreement regarding lesion localization (same quadrant) was 94.3% for ABVS and MRI and 91.2% for HHUS and MRI. Lesion size compared to MRI lesion size was assessed correctly (+/- 3 mm) in 79.4% (HHUS) and 80% (ABVS). The correlation of size measurement was slightly higher for ABVS-MRI (r = 0.89) than for HHUS-MRI (r = 0.82) with P < .001.

CONCLUSIONS: ABVS can be used as an alternative to HHUS. ABVS has the advantage of operator independence and better reproducibility although it is limited in evaluating axillary lymph nodes and lacks Doppler or elastrography capabilities, which sometimes provide important supplementary information in HHUS.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Schmachtenberg C, Fischer T, Hamm B, et al. Diagnostic Performance of Automated Breast Volume Scanning (ABVS) Compared to Handheld Ultrasonography With Breast MRI as the Gold Standard. Acad Radiol. 2017. PMID: 28336007. doi:10.1016/j.acra.2017.01.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。