文献速递乳腺MR

超快速乳腺MRI得到的强化时间作为鉴别乳腺良恶性病变的新参数

Time to enhancement derived from ultrafast breast MRI as a novel parameter to discriminate benign from malignant breast lesions.
PubMed 文献 · Eur J Radiol · 2017-01-20

回顾性纳入157例女性195个强化异常(99恶性、96良性),采用含超快速TWIST序列的双时间MRI协议,评估强化时间(TTE)并与VIBE曲线类型及形态学信息比较。TTE鉴别良恶性能力显著优于曲线类型,联合形态学后敏感度相当,但特异度和诊断准确率显著更高,读者间一致性好。

要点

  • TTE鉴别乳腺良恶性病变能力显著优于VIBE曲线类型(p<0.001和p=0.026)。
  • 联合形态学信息后,TWIST与VIBE评估敏感度相当,但TWIST特异度和准确率显著更高(p<0.001)。
  • TWIST评估鉴别良恶性的读者间一致性几乎完美(κ=0.86),常规评估为中等一致(κ=0.75)。

核心结论

  • 超快速TWIST序列衍生的强化时间(TTE)是有价值的参数,能以高准确率稳健鉴别乳腺良恶性病变。

研究设计与样本

  • 回顾性研究纳入157例女性195个强化异常(99个恶性、96个良性),采用含超快速TWIST序列(空间分辨率1.0×0.9×2.5mm,时间分辨率4.32s)的双时间MRI协议,参考标准为病理。

关键影像表现/征象

  • TTE从TWIST序列获得,相对强化-时间曲线类型从VIBE序列获得,两者均结合基本形态学信息用于鉴别良恶性。

诊断标准与关键数值

  • TTE鉴别良恶性能力显著优于曲线类型(读者1 p<0.001,读者2 p=0.026)。
  • 联合形态学后,TWIST与VIBE评估敏感度相当(读者1 p=0.549,读者2 p=0.344)。
  • 联合形态学后,TWIST评估的特异度和诊断准确率显著高于VIBE评估(p<0.001)。
  • 鉴别良恶性的读者间一致性:TWIST评估κ=0.86(几乎完美),常规评估κ=0.75(中等一致)。

临床应用与阅片要点

  • TTE可作为乳腺MRI病变分类的新型动态参数,辅助鉴别良恶性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate time to enhancement (TTE) as novel dynamic parameter for lesion classification in breast magnetic resonance imaging (MRI).

METHODS: In this retrospective study, 157 women with 195 enhancing abnormalities (99 malignant and 96 benign) were included. All patients underwent a bi-temporal MRI protocol that included ultrafast time-resolved angiography with stochastic trajectory (TWIST) acquisitions (1.0×0.9×2.5mm, temporal resolution 4.32s), during the inflow of contrast agent. TTE derived from TWIST series and relative enhancement versus time curve type derived from volumetric interpolated breath-hold examination (VIBE) series were assessed and combined with basic morphological information to differentiate benign from malignant lesions. Receiver operating characteristic analysis and kappa statistics were applied.

RESULTS: TTE had a significantly better discriminative ability than curve type (p<0.001 and p=0.026 for reader 1 and 2, respectively). Including morphology, sensitivity of TWIST and VIBE assessment was equivalent (p=0.549 and p=0.344, respectively). Specificity and diagnostic accuracy were significantly higher for TWIST than for VIBE assessment (p<0.001). Inter-reader agreement in differentiating malignant from benign lesions was almost perfect for TWIST evaluation (κ=0.86) and substantial for conventional assessment (κ=0.75).

CONCLUSIONS: TTE derived from ultrafast TWIST acquisitions is a valuable parameter that allows robust differentiation between malignant and benign breast lesions with high accuracy.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Mus RD, Borelli C, Bult P, et al. Time to enhancement derived from ultrafast breast MRI as a novel parameter to discriminate benign from malignant breast lesions. Eur J Radiol. 2017. PMID: 28267555. doi:10.1016/j.ejrad.2017.01.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。