文献速递乳腺MR

坏死/壁ADC比值是否有助于乳腺良恶性病变的鉴别

Is the necrosis/wall ADC ratio useful for the differentiation of benign and malignant breast lesions?
PubMed 文献 · Br J Radiol · 2017-03-24

本研究回顾性纳入66例女性患者(38例坏死性乳腺癌、28例乳腺脓肿),在3-T乳腺MRI的DWI上分别测量坏死区与壁的ADC值并计算坏死/壁ADC比值。癌的坏死/壁ADC比值均值为1.61±0.51,脓肿为0.65±0.33;坏死/壁ADC比值的AUC为0.942,以壁/坏死ADC比值截断值1.18判定恶性时敏感度97%、特异度93%、阳性预测值95%、阴性预测值96%、准确率95%。作者认为坏死/壁ADC比值似乎是鉴别乳腺癌与脓肿的可靠且有前景的工具。

要点

  • 坏死/壁ADC比值在乳腺癌为1.61±0.51,在脓肿为0.65±0.33。
  • 坏死/壁ADC比值AUC为0.942,高于坏死ADC的0.680和壁ADC的0.068。
  • 以壁/坏死ADC比值1.18为截断值判定恶性,敏感度97%、特异度93%、准确率95%。

核心结论

  • 坏死/壁ADC比值似乎是利用DWI鉴别乳腺癌与脓肿的可靠且有前景的工具。
  • DWI获得的坏死区ADC值对坏死性乳腺病变的良恶性鉴别有价值。

研究设计与样本

  • 回顾性研究,共纳入66例女性患者,其中38例为坏死性乳腺癌、28例为乳腺脓肿。
  • 使用3-T系统行乳腺MRI,基于DWI分别测量病变坏死区与壁的ADC值并计算坏死/壁ADC比值。
  • 通过同步对比增强T1加权图像区分壁与坏死区,所有诊断均经病理证实。
  • 统计分析采用独立样本t检验和受试者工作特征分析,并评估组内与组间相关性。

关键影像表现/征象

  • 癌的坏死/壁ADC比值均值为1.61±0.51,脓肿为0.65±0.33。
  • 坏死ADC、壁ADC和坏死/壁ADC比值的曲线下面积分别为0.680、0.068和0.942。
  • 坏死区与壁的ADC值均具有良好的组内和组间信度。

诊断标准与关键数值

  • 以壁/坏死ADC比值截断值1.18判定坏死性乳腺病变为恶性时,敏感度97%、特异度93%、阳性预测值95%、阴性预测值96%、准确率95%。

临床应用与阅片要点

  • 在DWI上分别测量坏死区与壁的ADC值并计算坏死/壁ADC比值,可能有助于乳腺癌与脓肿的鉴别。
  • 原文采用的判定方向为壁/坏死ADC比值,截断值1.18对应判定恶性,阅读文献时需注意与坏死/壁ADC比值的方向差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine whether the necrosis/wall apparent diffusion coefficient (ADC) ratio is useful for the malignant-benign differentiation of necrotic breast lesions.

METHODS: Breast MRI was performed using a 3-T system. In this retrospective study, calculation of the necrosis/wall ADC ratio was based on ADC values measured from the necrosis and from the wall of malignant and benign breast lesions by diffusion-weighted imaging (DWI). By synchronizing post-contrast T1 weighted images, the separate parts of wall and necrosis were maintained. All the diagnoses were pathologically confirmed. Statistical analyses were conducted using an independent sample t-test and receiver operating characteristic analysis. The intraclass and interclass correlations were evaluated.

RESULTS: A total of 66 female patients were enrolled, 38 of whom had necrotic breast carcinomas and 28 of whom had breast abscesses. The ADC values were obtained from both the wall and necrosis. The mean necrosis/wall ADC ratio (± standard deviation) was 1.61 ± 0.51 in carcinomas, and it was 0.65 ± 0.33 in abscesses. The area under the curve values for necrosis ADC, wall ADC and the necrosis/wall ADC ratio were 0.680, 0.068 and 0.942, respectively. A wall/necrosis ADC ratio cut-off value of 1.18 demonstrated a sensitivity of 97%, specificity of 93%, a positive-predictive value of 95%, a negative-predictive value of 96% and an accuracy of 95% in determining the malignant nature of necrotic breast lesions. There was a good intra- and interclass reliability for the ADC values of both necrosis and wall.

CONCLUSION: The necrosis/wall ADC ratio appears to be a reliable and promising tool for discriminating breast carcinomas from abscesses using DWI. Advances in knowledge: ADC values of the necrosis obtained by DWI are valuable for malignant-benign differentiation in necrotic breast lesions. The necrosis/wall ADC ratio appears to be a reliable and promising tool in the breast imaging field.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Durur-Subasi I, Durur-Karakaya A, Karaman A, et al. Is the necrosis/wall ADC ratio useful for the differentiation of benign and malignant breast lesions? Br J Radiol. 2017. PMID: 28339285. doi:10.1259/bjr.20160803

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。