文献速递乳腺乳腺X线

筛查检出与间期癌症:弗拉芒乳腺癌筛查规划中影像方式与乳腺密度的影响

Screen-detected versus interval cancers: Effect of imaging modality and breast density in the Flemish Breast Cancer Screening Programme.
PubMed 文献 · Eur Radiol · 2017-03-13

研究纳入2009至2010年弗拉芒乳腺癌筛查规划的351532名女性,比较直接数字化X线摄影(DR)、屏-片乳腺摄影(SF)和计算机X线摄影(CR)在不同BI-RADS密度分类中对筛查检出癌与间期癌的影响。总体67%的乳腺癌为筛查检出、33%为间期癌,DR表现优于SF和CR;间期癌率随乳腺密度增加而逐渐升高,与影像方式无关;在高密度类中SF和CR的间期癌率超过癌症检出率,而DR未超过。

要点

  • 间期癌率随乳腺密度增加而逐渐升高,与所用影像方式无关。
  • 高密度乳腺中DR的癌症检出率优于SF和CR。
  • 高密度乳腺中SF和CR的间期癌率超过癌症检出率,DR未超过。

核心结论

  • 在高密度乳腺中,DR在癌症检出率方面优于SF和CR;为降低高密度乳腺的高间期癌率,可考虑在筛查中加用其他影像技术。

研究设计与样本

  • 研究队列为2009年和2010年参加弗拉芒乳腺癌筛查规划的351532名女性,通过链接癌症检测中心与比利时癌症登记处数据库获取筛查检出癌、间期癌、放射科第二阅片者乳腺密度评分及影像方式信息。

诊断标准与关键数值

  • 总体67%的发生乳腺癌为筛查检出、33%为间期癌,DR表现优于SF和CR。
  • 间期癌率随乳腺密度增加而逐渐升高,与影像方式无关。
  • 高密度类中,SF和CR的间期癌率超过癌症检出率,DR未超过。
  • 高密度乳腺中DR的癌症检出率优于SF和CR。
  • DR在高密度乳腺的第三阅片和假阳性方面表现更好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate if direct radiography (DR) performs better than screen-film mammography (SF) and computed radiography (CR) in dense breasts in a decentralized organised Breast Cancer Screening Programme. To this end, screen-detected versus interval cancers were studied in different BI-RADS density classes for these imaging modalities.

METHODS: The study cohort consisted of 351,532 women who participated in the Flemish Breast Cancer Screening Programme in 2009 and 2010. Information on screen-detected and interval cancers, breast density scores of radiologist second readers, and imaging modality was obtained by linkage of the databases of the Centre of Cancer Detection and the Belgian Cancer Registry.

RESULTS: Overall, 67% of occurring breast cancers are screen detected and 33% are interval cancers, with DR performing better than SF and CR. The interval cancer rate increases gradually with breast density, regardless of modality. In the high-density class, the interval cancer rate exceeds the cancer detection rate for SF and CR, but not for DR.

CONCLUSIONS: DR is superior to SF and CR with respect to cancer detection rates for high-density breasts. To reduce the high interval cancer rate in dense breasts, use of an additional imaging technique in screening can be taken into consideration.

KEY POINTS: • Interval cancer rate increases gradually with breast density, regardless of modality. • Cancer detection rate in high-density breasts is superior in DR. • IC rate exceeds CDR for SF and CR in high-density breasts. • DR performs better in high-density breasts for third readings and false-positives.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Timmermans L, Bleyen L, Bacher K, et al. Screen-detected versus interval cancers: Effect of imaging modality and breast density in the Flemish Breast Cancer Screening Programme. Eur Radiol. 2017. PMID: 28289944. doi:10.1007/s00330-017-4757-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。