文献速递妇产影像US

校正估计胎儿体重后的脑胎盘比率对不良围产结局的预测

Prediction of adverse perinatal outcome by cerebroplacental ratio adjusted for estimated fetal weight.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-02-07

该回顾性队列研究纳入3515例单胎妊娠(3016例低危、499例高危),于孕30周后行脐动脉与胎儿大脑中动脉多普勒检查,评估脑胎盘比率(CPR)与估计胎儿体重(EFW)的关系及其对不良围产结局的预测价值。线性回归显示EFW百分位与CPR-MoM呈显著正相关;CPR-MoM与aCPR-MoM对不良围产结局的检出率均较低,在10%假阳性率下为0%至33.3%不等。作者建议CPR-MoM应按EFW百分位校正。

要点

  • EFW百分位与CPR-MoM呈显著正相关,CPR-MoM取值依赖EFW百分位。
  • CPR-MoM与aCPR-MoM对不良围产结局的检出率均低,10%假阳性率下为0%至33.3%。
  • 校正EFW后aCPR-MoM与更多结局指标相关,但预测率仍低。

核心结论

  • CPR-MoM值依赖EFW百分位,作者建议CPR-MoM应按EFW百分位校正;但CPR-MoM与aCPR-MoM对不良围产结局的预测率均低。

研究设计与样本

  • 回顾性队列研究,纳入2010年1月至2016年3月分娩的3515例单胎妊娠(3016例低危、499例高危),于孕30周后行脐动脉与胎儿大脑中动脉多普勒检查;按EFW百分位分为小于胎龄儿(EFW<第10百分位)、适于胎龄儿和大于胎龄儿(EFW>第90百分位)三组。

诊断标准与关键数值

  • CPR计算为脐动脉搏动指数(PI)与大脑中动脉PI的比值,并按三个EFW组转换为CPR中位数倍数(MoMs);按EFW百分位校正后得到aCPR-MoMs;不良围产结局定义为病理性胎心监护(CTG)描记、动脉脐血pH<7.1、5分钟Apgar评分<7及胎粪污染羊水(MSAF)存在。

临床应用与阅片要点

  • CPR-MoM与病理性CTG描记相关(AUC 0.539,SD 0.014,P=0.005)及低Apgar评分相关(AUC 0.609,SD 0.041,P=0.008),但与低动脉pH或MSAF无显著关联;aCPR-MoM与病理性CTG描记相关(AUC 0.540,SD 0.014,P=0.003)、低动脉脐血pH相关(AUC 0.546,SD 0.022,P=0.035)及低Apgar评分相关(AUC 0.609,SD 0.044,P=0.008),但与MSAF无显著关联;10%假阳性率下检出率:SGA组6.7%至28.6%、AGA组12.1%至22.2%、LGA组0%至33.3%;孕34周及以上且分娩前4周内行超声检查的亚组(n=1439)中,aCPR-MoM的ROC曲线与全部四项结局显著相关。

局限性

  • CPR-MoM与aCPR-MoM对不良围产结局的检出率均低,10%假阳性率下为6.7%至28.6%(SGA)、12.1%至22.2%(AGA)和0%至33.3%(LGA)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the relationship between cerebroplacental ratio (CPR) and estimated fetal weight (EFW) in low- and high-risk singleton pregnancies. Furthermore, we evaluated the role of CPR in the prediction of adverse perinatal outcome and whether CPR measurements adjusted for EFW improve its predictive value.

METHODS: This was a retrospective cohort study including pregnancies in which Doppler investigations of umbilical artery (UA) and fetal middle cerebral artery (MCA) were performed at ≥ 30 weeks' gestation. Pregnancies were allocated to one of three groups according to EFW centile: small-for-gestational age (SGA) with EFW < 10th centile, appropriate-for-gestational age (AGA) and large-for-gestational age (LGA) with EFW > 90th centile. CPR was calculated as the ratio between the UA pulsatility index (PI) and MCA-PI and converted to CPR multiples of the median (MoMs) according to the three EFW groups. Linear regression analysis was performed to evaluate the relationship between CPR-MoMs and EFW centiles in low-risk pregnancies. Furthermore, MoMs of CPR adjusted according to EFW centile (aCPR-MoMs) were calculated. Adverse perinatal outcome was defined as presence of pathological cardiotocography (CTG) trace, arterial cord blood pH < 7.1, 5-min Apgar score < 7 and presence of meconium-stained amniotic fluid (MSAF).

RESULTS: A total of 3515 (3016 low risk and 499 high risk) pregnancies, delivered between January 2010 and March 2016, were included. Linear regression analysis revealed a significant positive correlation between EFW centile and CPR-MoM. Receiver-operating characteristics (ROC) curve analysis showed a significant association between CPR-MoM and pathological CTG trace (AUC, 0.539; SD, 0.014; P = 0.005) and low Apgar score (AUC, 0.609; SD, 0.041; P = 0.008), but not with low arterial pH or MSAF. There was a significant association between aCPR-MoM and pathological CTG trace (AUC, 0.540; SD, 0.014; P = 0.003), low arterial cord blood pH (AUC, 0.546; SD, 0.022; P = 0.035) and low Apgar score (AUC, 0.609; SD, 0.044; P = 0.008), but not with MSAF. However, detection rates for adverse perinatal outcomes by CPR-MoM and aCPR-MoM were low, ranging from 6.7% to 28.6% for SGA, 12.1% to 22.2% for AGA and 0% to 33.3% for LGA, for a false-positive rate of 10%. In a subgroup analysis of cases in which ultrasound examination was performed at ≥ 34 weeks of gestation and within 4 weeks of delivery (n = 1439), the ROC curves for aCPR-MoM were significantly associated with all four outcomes evaluated.

CONCLUSIONS: CPR-MoM values are dependent on EFW centiles; therefore, we suggest that CPR-MoM should be adjusted for EFW centile. However, both CPR- and aCPR-MoM showed a low prediction rate for adverse perinatal outcome. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Sirico A, Diemert A, Glosemeyer P, et al. Prediction of adverse perinatal outcome by cerebroplacental ratio adjusted for estimated fetal weight. Ultrasound Obstet Gynecol. 2018. PMID: 28294442. doi:10.1002/uog.17458

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。