文献速递妇产影像US

基于新型图像评分法对荷兰西南地区孕中期胎儿畸形筛查的审核

An Audit of Second-Trimester Fetal Anomaly Scans Based on a Novel Image-Scoring Method in the Southwest Region of the Netherlands.
PubMed 文献 · J Ultrasound Med · 2017-03-16

2007年起荷兰全国产前筛查计划向所有孕妇提供孕中期胎儿畸形筛查,2012年因缺乏统一监测系统,研究者开发标准化图像评分法。本研究评估荷兰西南地区所有超声医师的扫查表现,85名医师的425份日志被审核,86%初次审核达标,12名需一对一培训,复审核11名达标、1名终止合同。

要点

  • 图像评分法以每份日志25个胎儿解剖结构及6项生物学测量为审核内容。
  • 85名超声医师中73名(86%)初次审核达标,12名需一对一培训。
  • 复审中11名培训者达标,1名超声医师终止合同。

核心结论

  • 图像评分法质量评估显示多数超声医师达到审核预期,表现欠佳者经再培训后达到预期。

研究设计与样本

  • 质量审核研究,纳入荷兰西南地区85名超声医师的425份日志,每份日志含5名不同孕妇的孕中期胎儿畸形筛查图像,每名孕妇包含25个胎儿解剖结构和6项生物学测量,以标准化图像评分法为审核标准。

诊断标准与关键数值

  • 每份日志需包含25个胎儿解剖结构和6项生物学测量;初次审核中85名超声医师73名(86%)达标,12名需一对一培训;复审中11名达标、1名终止合同。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 2.1%的所需图像未以数字形式存储,因此无法审核。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Since 2007 the second-trimester fetal anomaly scan is offered to all pregnant women as part of the national prenatal screening program in the Netherlands. Dutch population-based screening programs generally have a well-described system to achieve quality assurance. Because of the absence of a uniform system to monitor the actual performance of the fetal anomaly scan in 2012, we developed a standardized image-scoring method. The aim of this study was to evaluate the scanning performance of all sonographers in the southwestern region of the Netherlands using this image-scoring method.

METHODS: Each sonographer was requested to set up a digital portfolio. A portfolio consists of five logbooks from five different pregnant women, each containing 25 fetal anatomical structures and six biometric measures of randomly selected fetal anomaly scans.

RESULTS: During the study period, 425 logbooks of 85 sonographers were assessed as part of the audit process. Seventy-three out of 85 sonographers (86%) met the criteria in the primary audit, and 12 sonographers required individual hands-on training. A successful assessment was achieved for 11 sonographers in the re-audit and one sonographer ceased her contract. Moreover, 2.1% of the required images were not digitally stored and therefore could not be reviewed.

CONCLUSIONS: Quality assessment using the image-scoring method demonstrated that most of the sonographers met the expectations of the audit process, but those who had subpar performance met the expectations after retraining.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ursem NTC, Peters IA, Kraan-van der Est MN, et al. An Audit of Second-Trimester Fetal Anomaly Scans Based on a Novel Image-Scoring Method in the Southwest Region of the Netherlands. J Ultrasound Med. 2017. PMID: 28299806. doi:10.7863/ultra.16.06055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。