低剂量基于模型的迭代重建与标准剂量自适应统计迭代重建在泌尿系结石CT诊断与随访中的患者内比较

Intra-patient comparison of reduced-dose model-based iterative reconstruction with standard-dose adaptive statistical iterative reconstruction in the CT diagnosis and follow-up of urolithiasis.
PubMed 文献 · Eur Radiol · 2017-03-13

单机构前瞻性研究纳入125例急性肾绞痛或已知泌尿系结石随访患者,同一患者连续接受标准剂量与最低剂量CT扫描,低剂量图像分别用ASIR 30%和MBIR重建。低剂量MBIR对输尿管结石评估与参考标准100%一致,对3 mm及以上结石识别极准确,允许剂量降低58%而无扫描质量损失。

要点

  • 低剂量MBIR扫描对输尿管结石评估与参考标准100%一致。
  • MBIR可准确识别3 mm及以上结石。
  • 低剂量MBIR较标准剂量降低58%剂量且无扫描质量损失。

核心结论

  • 低剂量CT使用MBIR重建在急性肾绞痛成像和泌尿系结石随访中准确,并允许显著降低剂量。

研究设计与样本

  • 单机构前瞻性研究,纳入125例表现为急性肾绞痛或已知泌尿系结石随访的患者,连续接受标准剂量与最低剂量(最高噪声指数)两次扫描,低剂量扫描用ASIR 30%和MBIR重建,由两名放射科医生独立阅片。

诊断标准与关键数值

  • 低剂量MBIR扫描对输尿管结石评估与参考标准100%一致。
  • 低剂量MBIR对3 mm及以上结石识别极准确。
  • MBIR允许剂量降低58%而无扫描质量损失。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the accuracy of reduced-dose CT scans reconstructed using a new generation of model-based iterative reconstruction (MBIR) in the imaging of urinary tract stone disease, compared with a standard-dose CT using 30% adaptive statistical iterative reconstruction.

METHODS: This single-institution prospective study recruited 125 patients presenting either with acute renal colic or for follow-up of known urinary tract stones. They underwent two immediately consecutive scans, one at standard dose settings and one at the lowest dose (highest noise index) the scanner would allow. The reduced-dose scans were reconstructed using both ASIR 30% and MBIR algorithms and reviewed independently by two radiologists. Objective and subjective image quality measures as well as diagnostic data were obtained.

RESULTS: The reduced-dose MBIR scan was 100% concordant with the reference standard for the assessment of ureteric stones. It was extremely accurate at identifying calculi of 3 mm and above. The algorithm allowed a dose reduction of 58% without any loss of scan quality.

CONCLUSIONS: A reduced-dose CT scan using MBIR is accurate in acute imaging for renal colic symptoms and for urolithiasis follow-up and allows a significant reduction in dose.

KEY POINTS: • MBIR allows reduced CT dose with similar diagnostic accuracy • MBIR outperforms ASIR when used for the reconstruction of reduced-dose scans • MBIR can be used to accurately assess stones 3 mm and above.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Tenant S, Pang CL, Dissanayake P, et al. Intra-patient comparison of reduced-dose model-based iterative reconstruction with standard-dose adaptive statistical iterative reconstruction in the CT diagnosis and follow-up of urolithiasis. Eur Radiol. 2017. PMID: 28289943. doi:10.1007/s00330-017-4783-2