妊娠中晚期三维胎儿体积测量的检查者内与检查者间变异性

Intraexaminer and Interexaminer Variability in 3D Fetal Volume Measurements During the Second and Third Trimesters of Pregnancy.
PubMed 文献 · J Ultrasound Med · 2017-03-24

研究由2名经验丰富的盲法超声医师对58例21至39周胎儿行三维器官体积测量,评估检查者内与检查者间信度。第二孕期肾脏体积检查者间误差最大(95%一致性界限±110%),第三孕期股部部分体积一致性最好(±25%);除第二孕期肾脏体积及胎盘检查者间、第三孕期肾脏检查者间外,组内相关系数均大于0.75。作者认为头、肾、全股部及胎盘三维体积可重复性有限,常规用于评估胎儿生长前需改进测量技术,而第三孕期晚期股部部分体积可可靠获得。

要点

  • 第二孕期肾脏体积检查者间误差最大,95%一致性界限达±110%。
  • 第三孕期股部部分体积一致性最好,95%一致性界限为±25%。
  • 除第二孕期肾脏体积及胎盘检查者间、第三孕期肾脏检查者间外,ICC均大于0.75。

核心结论

  • 三维胎儿头、肾、全股部及胎盘体积的可重复性有限,常规用于评估胎儿生长前需改进测量技术;第三孕期晚期股部部分体积可可靠获得。

研究设计与样本

  • 由2名经验丰富的盲法超声医师对58例21至39周胎儿行三维胎儿器官体积(头、肾、全股部体积及股部部分体积,第二孕期另加胎盘体积)测量,用Bland-Altman图、95%一致性界限及组内相关系数评估检查者内与检查者间信度。

诊断标准与关键数值

  • 检查者间误差最大为第二孕期肾脏体积(95%一致性界限±110%);一致性最好为第三孕期股部部分体积(95%一致性界限±25%)及第二孕期头部体积(95%一致性界限-7%至25%)。第二、三孕期ICC均大于0.75,除外第二孕期肾脏体积检查者内(0.374)与检查者间(0.061)、第二孕期胎盘检查者间(0.390)及第三孕期肾脏检查者间(0.647)。

临床应用与阅片要点

  • 作者认为头、肾、全股部及胎盘三维体积可重复性有限,常规用于评估胎儿生长前需改进测量技术。
  • 作者指出第三孕期晚期股部部分体积可可靠获得。

局限性

  • 作者指出头、肾、全股部及胎盘三维体积可重复性有限,常规用于评估胎儿生长前需改进测量技术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess intraexaminer and interexaminer reliability of 3-dimensional fetal sonographic measurements.

METHODS: Three-dimensional fetal organ volumes (head, kidney, total thigh volume, and fractional thigh volume) were acquired during the second and third trimesters, with the addition of placental volume in the second trimester, by 2 different experienced, blinded sonographers. Fifty-eight fetuses were examined from 21 to 39 weeks' gestation. Intraexaminer and Interexaminer reliability was assessed with Bland-Altman plots, and their 95% limits of agreement and intraclass correlation coefficients.

RESULTS: The most significant interexaminer error was observed in the second-trimester kidney volume (95% limits of agreement, ± 110%), and the best agreement was for the third-trimester fractional thigh volume (95% limits of agreement, ± 25%) and second-trimester head volume (95% limits of agreement, -7%-25%). Second- and third-trimester intraclass correlation coefficient results were all greater than 0.75, apart from second-trimester kidney volume intraexaminer (0.374) and interexaminer (0.061) measurements, second-trimester placenta interexaminer measurements (0.390), and third-trimester kidney interexaminer measurements (0.647).

CONCLUSIONS: Three-dimensional fetal sonographic volumes of the head, kidney, total thigh, and placenta have limited reproducibility, and improvements in measurement techniques are needed before they can be used routinely to assess fetal growth. The 3-dimensional fractional thigh volume can be reliably obtained in the late third trimester.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Simcox LE, Higgins LE, Myers JE, et al. Intraexaminer and Interexaminer Variability in 3D Fetal Volume Measurements During the Second and Third Trimesters of Pregnancy. J Ultrasound Med. 2017. PMID: 28339117. doi:10.7863/ultra.16.03045

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。