文献速递泌尿生殖腹部CT

分次团注CT尿路造影:少即是多?

Split-bolus CT urogram: Is less more?
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

回顾性分析339例无特殊输尿管扩张操作的分次团注CT尿路造影(SB-CTU),对照膀胱镜、输尿管镜和/或泌尿科临床随访计算诊断准确性。上尿路尿路上皮癌检出敏感度80%、特异度99%、阳性预测值44%、阴性预测值100%;膀胱肿瘤检出敏感度55%、特异度98%、阳性预测值78%、阴性预测值95%。

要点

  • 无特殊输尿管扩张操作的SB-CTU对上尿路尿路上皮癌敏感度80%、阴性预测值100%,但阳性预测值仅44%。
  • 上尿路尿路上皮癌患病率1.5%,膀胱肿瘤9.7%,患病率随患者年龄和临床指征显著变化。
  • 膀胱肿瘤检出敏感度仅55%,上尿路与膀胱肿瘤阳性预测值分别为44%和78%。

核心结论

  • 基于本研究,无特殊输尿管扩张操作的分次团注CT尿路造影对上尿路尿路上皮癌检出高度敏感,但阳性预测值低,假阳性确实存在。通过其他更复杂的CT尿路造影方案提高这一低患病率疾病诊断准确性的临床效用,应与这些方案相关的额外成本和辐射剂量权衡。

诊断标准与关键数值

  • 上尿路尿路上皮癌检出:敏感度80%、特异度99%、阳性预测值44%、阴性预测值100%;膀胱肿瘤检出:敏感度55%、特异度98%、阳性预测值78%、阴性预测值95%;上尿路尿路上皮癌5例(患病率1.5%),膀胱肿瘤33例(患病率9.7%);上尿路尿路上皮癌假阴性1例、假阳性4例。

临床应用与阅片要点

  • 作者认为,无特殊输尿管扩张操作的SB-CTU对上尿路尿路上皮癌检出高度敏感但阳性预测值低,假阳性确实存在;通过其他更复杂CT尿路造影方案提高诊断准确性的临床效用应与额外成本和辐射剂量权衡。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the accuracy of split-bolus CT urogram (SB-CTU) without special maneuvers for ureteral distention in diagnosing upper urinary tract urothelial carcinoma (UCA).

MATERIALS AND METHODS: A hospital database was searched from 1/1/10, to 9/1/15, for SB-CTU exams without special maneuvers for ureteral distention. Accuracy of SB-CTU for detecting upper and lower urinary tract UCA was computed by comparing the prospective radiology report with cystoscopy, ureteroscopy, and/or urologic clinical follow-up. Patients with less than 12 months of clinical follow-up were excluded.

RESULTS: 339 studies were identified in 334 patients (60% male 40% female, avg. age 64). 119 studies were performed for microhematuria, 150 for gross hematuria, 13 for hematuria not otherwise specified, 57 for history of UCA, and one for a collecting system mass on a prior CT. There were five upper tract and 33 bladder tumors with overall prevalence of 1.5% and 9.7%, respectively. The prevalence varied significantly with patient age and clinical indication for SB-CTU. There were one false negative and four false positives for upper urinary tract UCA. Sensitivity, specificity, positive predictive value, and negative predictive value for detecting upper tract and bladder tumors were 80%, 99%, 44%, and 100%, respectively, and 55%, 98%, 78%, and 95%, respectively.

CONCLUSION: Based on this study, SB-CTU without special maneuvers for ureteral distention is highly sensitive for detecting upper tract UCA, although with a low positive predictive value, false positives do occur. The clinical utility of increasing accuracy in diagnosing this low-prevalence disease through other more complex CT urogram protocols should be weighed against the added cost and radiation dose associated with these protocols.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Shaish H, Newhouse JH. Split-bolus CT urogram: Is less more? Abdom Radiol (NY). 2017. PMID: 28271274. doi:10.1007/s00261-017-1098-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。