经会阴3-T磁共振引导前列腺穿刺活检样本与根治性前列腺切除标本的病理对照研究
回顾性分析2010至2015年24例接受经会阴3-T磁共振引导前列腺穿刺活检(tpMRGB)并在1年内行根治性前列腺切除术的患者,tpMRGB与根治标本Gleason评分一致17例(71%),相关性ρ=+0.75(p<0.001);16例既往经直肠超声引导穿刺者中,tpMRGB使88%病例Gleason升级,与根治标本一致率69%。
要点
- tpMRGB与根治标本Gleason评分一致率71%,强相关(ρ=+0.75,p<0.001)。
- 既往TRUS穿刺者中tpMRGB使88%病例Gleason升级,与根治标本一致率69%。
- tpMRGB对最终Gleason评分预测准确,尤其适用于TRUS阴性或低级别但mpMRI可疑的患者。
核心结论
- 3-T下tpMRGB诊断的最终Gleason评分与根治性前列腺切除病理强相关,可能有助于前列腺癌诊断,尤其适用于TRUS活检阴性或低级别而临床怀疑或mpMRI检测到临床显著癌的患者。
研究设计与样本
- 回顾性研究,纳入2010至2015年24例接受经会阴3-T磁共振引导前列腺穿刺活检并在1年内行根治性前列腺切除术的男性;所有患者先行3-T多参数MRI(含直肠内线圈),基于MR可疑病灶和高临床怀疑度选择活检;采用Spearman相关评估tpMRGB与根治病理的一致性,并按有无既往经直肠超声引导穿刺分层。
诊断标准与关键数值
- tpMRGB与根治标本Gleason评分一致17例(71%);总体相关性ρ=+0.75(p<0.001);16例有既往TRUS穿刺者中tpMRGB显示Gleason升级占88%,与根治标本Gleason评分一致率69%(ρ=+0.75,p<0.001)。
临床应用与阅片要点
- 作者认为3-T下tpMRGB与根治病理强相关,可能有助于前列腺癌诊断,尤其适用于TRUS活检阴性或低级别而临床怀疑或mpMRI检测到临床显著癌的患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine the accuracy of in-bore transperineal 3-Tesla (T) magnetic resonance (MR) imaging-guided prostate biopsies for predicting final Gleason grades in patients who subsequently underwent radical prostatectomy (RP).
METHODS: A retrospective review of men who underwent transperineal MR imaging-guided prostate biopsy (tpMRGB) with subsequent radical prostatectomy within 1 year was conducted from 2010 to 2015. All patients underwent a baseline 3-T multiparametric MRI (mpMRI) with endorectal coil and were selected for biopsy based on MR findings of a suspicious prostate lesion and high degree of clinical suspicion for cancer. Spearman correlation was performed to assess concordance between tpMRGB and final RP pathology among patients with and without previous transrectal ultrasound (TRUS)-guided biopsies.
RESULTS: A total of 24 men met all eligibility requirements, with a median age of 65 years (interquartile range [IQR] 11.7). The median time from biopsy to RP was 85 days (IQR 50.5). Final pathology revealed Gleason 3 + 4 = 7 in 12 patients, 4 + 3 = 7 in 10 patients, and 4 + 4 = 8 in 2 patients. A strong correlation (ρ: +0.75, p < 0.001) between tpMRGB and RP results was observed, with Gleason scores concordant in 17 cases (71%). 16 of the 24 patients underwent prior TRUS biopsies. Subsequent tpMRGB revealed Gleason upgrading in 88% of cases, which was concordant with RP Gleason scores in 69% of cases (ρ: +0.75, p < 0.001).
CONCLUSION: Final Gleason scores diagnosed by tpMRGB at 3-T correlate strongly with final RP surgical pathology. This may facilitate prostate cancer diagnosis, particularly in patients with negative or low-grade TRUS biopsy results in whom clinically significant cancer is suspected or detected on mpMRI.
引用
- Velez E, Fedorov A, Tuncali K, et al. Pathologic correlation of transperineal in-bore 3-Tesla magnetic resonance imaging-guided prostate biopsy samples with radical prostatectomy specimen. Abdom Radiol (NY). 2017. PMID: 28293720. doi:10.1007/s00261-017-1102-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。