虚拟导航引导平板探测器锥形束CT经皮肾造瘘术用于医源性输尿管损伤患者
回顾性评估虚拟导航引导平板探测器锥形束CT(CBCT)经皮肾造瘘术在医源性输尿管损伤患者中的可行性。42例次(40例)均为超声引导失败后的二线干预,技术成功率95.2%(40/42),平均穿刺操作评分4.4±1.0,手术时间25.2±3.1分钟,平均有效曝光剂量5.9±2.3 mSv,无严重并发症。平均随访11.4个月(范围6-19),引流后临床成功率72.5%(29/40),10例(25%)接受二次手术治疗。作者认为该技术可行,可作为超声引导失败后的二线干预。
要点
- 所有操作均为超声引导经皮肾造瘘失败后的二线干预,技术成功率95.2%(40/42)。
- 平均穿刺操作评分4.4±1.0,手术时间25.2±3.1分钟,平均有效曝光剂量5.9±2.3 mSv。
- 无严重并发症;平均随访11.4个月(范围6-19),引流后临床成功率72.5%(29/40),10例(25%)接受二次手术治疗。
核心结论
- 虚拟导航引导平板探测器CBCT经皮肾造瘘术在医源性输尿管损伤患者中技术可行,曝光剂量合理,可作为超声引导失败后的二线干预。
研究设计与样本
- 回顾性研究,纳入42例次经皮肾造瘘术(40例患者),均因医源性输尿管损伤在超声引导失败后接受CBCT三维虚拟导航引导;收集技术成功率、手术时间、穿刺操作评分、辐射暴露、并发症及临床成功率数据。
诊断标准与关键数值
- 技术成功率95.2%(40/42)。
- 平均穿刺操作评分4.4±1.0。
- 手术时间25.2±3.1分钟,平均有效曝光剂量5.9±2.3 mSv。
- 平均随访11.4个月(范围6-19),引流后临床成功率72.5%(29/40),10例(25%)接受二次手术治疗。
临床应用与阅片要点
- 作者认为虚拟导航引导平板探测器CBCT经皮肾造瘘术技术可行、曝光剂量合理,可作为超声引导失败后的二线干预。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the feasibility of flat detector cone beam computed tomography (CBCT)-guided nephrostomy using virtual navigation in patients with iatrogenic ureteral injury.
MATERIALS AND METHODS: A retrospective review of percutaneous nephrostomy (PN) revealed the use of CBCT with 3D virtual navigation guidance in 42 procedures (40 patients) for patients with iatrogenic ureteral injury. All procedures were shown as second-line interventions after failed ultrasound-guided nephrostomy. Data on technical success rate, procedure time, puncture performance, radiation exposure, complications, and clinical success were collected.
RESULTS: The technical success rate was 95.2% (40/42). The mean puncture performance score was 4.4 ± 1.0, and the procedure time was 25.2 ± 3.1 min, resulting in a mean effective exposure dose of 5.9 ± 2.3 mSv. There were no serious complications. During the mean follow-up periods of 11.4 months (range 6-19), clinical success rates following drainage were 72.5% (29/40), and ten cases (25%) had secondary surgical treatments.
CONCLUSION: CBCT with 3D virtual navigation is a feasible technique for PN with reasonable exposure dose and can serve as a second-line intervention after failed ultrasound guidance.
引用
- Jiao D, Li Z, Li Z, et al. Flat detector cone beam CT-guided nephrostomy using virtual navigation in patients with iatrogenic ureteral injury. Radiol Med. 2017. PMID: 28332142. doi:10.1007/s11547-017-0751-9