文献速递腹部介入CTUS

疑似恶性胆道梗阻患者经皮腔内钳夹活检:271例患者结局的影响因素

Percutaneous transluminal forceps biopsy in patients suspected of having malignant biliary obstruction: factors influencing the outcomes of 271 patients.
PubMed 文献 · Eur Radiol · 2017-03-27

271例梗阻性黄疸患者行经皮腔内钳夹活检,每例取3至5份标本(平均3.5份),最终诊断经手术病理、其他组织细胞学数据或临床影像随访确认;活检诊断恶性灵敏度77.2%、特异度100%、准确率78.9%、阳性预测值100%、阴性预测值25.9%,壶腹周围段胆总管、肝内胆管及转移性疾病为假阴性诊断的显著危险因素。

要点

  • 经皮腔内钳夹活检诊断恶性胆道梗阻准确率78.9%,特异度100%,无假阳性。
  • 假阴性率为57/271,阴性预测值仅25.9%,阴性结果不能排除恶性。
  • 壶腹周围段胆总管、肝内胆管及转移性疾病是假阴性诊断的显著危险因素。

核心结论

  • 经皮钳夹活检诊断恶性胆道梗阻准确率相对较高,假阴性活检的预测因素为活检部位和原发肿瘤来源。

研究设计与样本

  • 连续纳入271例梗阻性黄疸患者行经皮钳夹活检,每例从病灶取3至5份标本(平均3.5份),最终诊断经手术病理、其他组织细胞学数据或临床影像随访确认,采用单因素和多因素logistic回归分析假阴性诊断的危险因素。

关键影像表现/征象

  • 271例活检中194例正确诊断为恶性,20例活检诊断为真阴性,57例为假阴性诊断,无假阳性诊断。
  • 壶腹周围段胆总管、肝内胆管和转移性疾病是假阴性诊断的显著危险因素。

诊断标准与关键数值

  • 经皮腔内钳夹活检诊断恶性胆道梗阻:灵敏度77.2%,特异度100%,准确率78.9%,阳性预测值100%,阴性预测值25.9%。

临床应用与阅片要点

  • 活检部位位于壶腹周围段胆总管或肝内胆管、或原发肿瘤为转移性疾病时,假阴性风险较高。
  • 阴性预测值仅25.9%,活检阴性结果不能排除恶性胆道梗阻。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate predictive factors for false-negative diagnosis of percutaneous forceps biopsies in patients suspected of having a malignant biliary obstruction METHODS: Two hundred seventy one consecutive patients with obstructive jaundice underwent percutaneous forceps biopsy. In each patient, three to five specimens (mean, 3.5 specimens) were collected from the lesion. The final diagnosis for each patient was confirmed with pathologic findings at surgery, additional histocytologic data, or clinical and radiologic follow-up. Univariate and multivariate logistic regression analysis was used to identify risk factors associated with false-negative diagnosis.

RESULTS: One hundred ninety four of 271 biopsies resulted in correct diagnoses of malignancy, while 20 biopsy diagnoses were proved to be true-negative. There were 57 false-negative diagnoses and no false-positive diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstructions was as follows: sensitivity, 77.2%; specificity, 100%; and accuracy, 78.9%; positive predictive value, 100%, negative predictive value; 25.9%. Periampullary segment of common bile duct, intrahepatic bile duct and metastatic disease were the significant risk factors of false-negative diagnosis.

CONCLUSIONS: Percutaneous forceps biopsy provides relatively high accuracy in the diagnosis of malignant biliary obstructions. The predictive factors of false-negative biopsy were determined to be biopsy site and origin of primary tumour.

KEY POINTS: • Percutaneous forceps biopsy provides relatively high accuracy in diagnosis of malignant biliary obstructions. • The predictive factors of false-negative biopsy were biopsy site and origin of primary tumour. • The procedure-related complications were low.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Park JG, Jung GS, Yun JH, et al. Percutaneous transluminal forceps biopsy in patients suspected of having malignant biliary obstruction: factors influencing the outcomes of 271 patients. Eur Radiol. 2017. PMID: 28349279. doi:10.1007/s00330-017-4796-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。