剪切波弹性成像评估人前列腺癌异种移植模型中肿瘤硬度
研究将人前列腺癌DU-145细胞注射入24只裸鼠,按移植后6、8、10周分3组,用二维超声和剪切波弹性成像记录肿瘤体积与杨氏模量,并行病理染色分析胶原比例。共收集19个肿瘤,体积与平均杨氏模量随移植时间增加,组1与组3的I/III型胶原面积比差异有统计学意义(0.50±0.17 vs 1.97±0.56,P<.01),杨氏模量与I/III型胶原面积比呈高度相关(r=0.968,P<.05)。
要点
- 剪切波弹性成像可用于显示人前列腺癌异种移植肿瘤的弹性。
- 肿瘤平均杨氏模量随移植时间(6、8、10周)增加。
- 胶原纤维尤其I型胶原在该模型肿瘤弹性中起关键作用。
核心结论
- 剪切波弹性成像是一项有用的新技术,可显示人前列腺癌异种移植肿瘤的弹性;胶原纤维尤其是I型胶原在该模型肿瘤弹性中起关键作用。
研究设计与样本
- 人前列腺癌异种移植模型研究,将DU-145细胞注射入24只裸鼠,按移植后6、8、10周分3组,用二维超声和剪切波弹性成像记录肿瘤体积、弹性及杨氏模量,并行苏木精-伊红、丽春红S、苯胺染色及苦味酸-天狼星红染色计算I/III型胶原面积比,行波形蛋白和α-平滑肌肌动蛋白免疫组化。
诊断标准与关键数值
- 硬肿瘤中胶原纤维更多;组1与组3的I/III型胶原面积比分别为0.50±0.17与1.97±0.56(P<.01);肿瘤杨氏模量与I/III型胶原面积比高度相关(r=0.968,P<.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the stiffness of human prostate cancer in a xenograft implantation model using shear wave elastography and compare the pathologic features of tumors with varying elasticity.
METHODS: Human prostate cancer DU-145 cells were injected into 24 nude male mice. The mice were divided into 3 groups according to the time of transplantation (6, 8, and 10 weeks). The volume, elasticity, and Young modulus of tumors were recorded by 2-dimensional sonography and shear wave elastography. The tumors were collected for pathologic analyses: hematoxylin-eosin staining, Ponceau S, and aniline staining were used to stain collagen and elastic fibers, and picric acid-sirius red staining was used to indicate type I and III collagen. The area ratios of collagen I/III were calculated. The correlation between the Young modulus of the tumor and area ratio of collagen I/III were evaluated. Immunohistochemistry of vimentin and α-smooth muscle actin was performed.
RESULTS: Nineteen tumors in 3 groups were collected. The volume and mean Young modulus increased with the time of transplantation. There were more collagen fibers in the stiff tumors, and there were significant differences in the area ratios of collagen I/III between groups 1 (mean ± SD, 0.50 ± 0.17) and 3 (1.97 ± 0.56; P < .01). The Young modulus of the tumors showed a very significant correlation with the area ratios of collagen I/III (r = 0.968; P < .05). The expression level of α-smooth muscle actin protein was higher in group 3 than in the other groups, but differences in vimentin expression were barely seen.
CONCLUSIONS: Shear wave elastography is a novel useful technology for showing the elasticity of human prostate cancer xenograft implantation tumors. Collagen fibers, especially collagen type I, play a crucial role in the elasticity in the human prostate cancer xenograft implantation model.