使用介入C臂系统动态测量肝动脉灌注
在5头猪的肝左叶栓塞模型中,采用选择性动脉造影注射行三次锥形束CT灌注(CBCTp)测量,评估两种扫描方案(3.3秒/166幅与4.5秒/248幅)的动脉肝灌注(ALP)与临床CT灌注(CTp)的一致性。两种CBCTp方案高度一致(一致性相关系数0.90,P<0.001),非靶叶可重复性均高于CTp(组内相关系数≥0.90 vs 0.83,P<0.001),与CTp一致性相关系数分别为0.75和0.87(P<0.001)。结论认为C臂系统动态血流测量可行,定量结果与CTp相当。
要点
- 两种CBCTp方案一致性相关系数0.90(P<0.001),扫描参数不同仍高度一致。
- 非靶叶可重复性CBCTp组内相关系数≥0.90,高于CTp的0.83(P<0.001)。
- 与CTp一致性:短方案0.75、长方案0.87(P均<0.001)。
核心结论
- 使用血管造影C臂系统进行动态血流测量是可行的,且产生的定量结果与CTp相当。
研究设计与样本
- 在5头猪的肝左叶完全栓塞模型中,于栓塞前后各行三次选择性动脉造影注射CBCTp测量。
- 评估两种CBCTp方案:扫描时长3.3秒与4.5秒,采集投影图像数166幅与248幅。
- 在每次扫描生成的灌注图上,于栓塞区与非栓塞区相同感兴趣体积内测量平均ALP。
- 栓塞后CBCTp值与CTp测量进行比较。
关键影像表现/征象
- 栓塞叶ALP接近零,因此被排除在可重复性分析之外。
诊断标准与关键数值
- 两种CBCTp方案间一致性相关系数为0.90(P<0.001)。
- 非靶叶可重复性:CBCTp组内相关系数≥0.90,CTp为0.83(所有相关性P<0.001)。
- CTp与短CBCTp方案一致性相关系数0.75,与长CBCTp方案0.87(两者P<0.001)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Objective intraprocedural measurement of hepatic blood flow could provide a quantitative treatment end point for locoregional liver procedures. This study aims to validate the accuracy and reproducibility of cone-beam computed tomography perfusion (CBCTp) measurements of arterial liver perfusion (ALP) against clinically available computed tomography perfusion (CTp) measurements in a swine embolization model.
METHODS: Triplicate CBCTp measurements using a selective arterial contrast injection were performed before and after complete embolization of the left lobe of the liver in 5 swine. Two CBCTp protocols were evaluated that differed in sweep duration (3.3 vs 4.5 seconds) and the number of acquired projection images (166 vs 248). The mean ALP was measured within identical volumes of interest selected in the embolized and nonembolized regions of the perfusion map generated from each scan. Postembolization CBCTp values were also compared with CTp measurements.
RESULTS: The 2 CBCTp protocols demonstrated high concordance correlation (0.90, P < 0.001). Both CBCTp protocols showed higher reproducibility than CTp in the nontarget lobe, with an intraclass correlation of 0.90 or greater for CBCTp and 0.83 for CTp (P < 0.001 for all correlations). The ALP in the embolized lobe was nearly zero and hence excluded for reproducibility. High concordance correlation was observed between the CTp and each CBCTp protocol, with the shorter CBCTp protocol reaching a concordance correlation of 0.75 and the longer achieving 0.87 (P < 0.001 for both correlations).
CONCLUSIONS: Dynamic blood flow measurement using an angiographic C-arm system is feasible and produces quantitative results comparable to CTp.