在单中心前瞻性纳入47例患者,获取54次常规超声与54次仅研究用床旁超声检查,9名盲法读片者对476对研究进行诊断。常规超声平均诊断准确率84%,高于床旁超声74%(P<.001);敏感度85%对75%,特异度68%对83%。当图像质量和诊断信心相当时两者准确率无差异。

要点

  • 常规超声平均诊断准确率84%,床旁超声74%(P<.001)。
  • 常规超声检测异常的敏感度85%、特异度83%;床旁超声分别为75%和68%。
  • 图像质量和诊断信心相当时,床旁与常规超声准确率无差异。

核心结论

  • 床旁超声对基础、聚焦检查的准确性几乎与常规超声相当,观察到的准确率差异归因于床旁超声图像质量变异更大。

研究设计与样本

  • 2010年3个月内在单中心前瞻性纳入47例患者,获取54次临床常规超声和54次仅研究用床旁超声检查。
  • 检查指征为腹部48%、腹膜后26%、产科24%。
  • 9名盲法读片者(超声技师、住院医师和主治放射科医师)依次对床旁和常规研究分配诊断,产生476对判读研究。
  • 以未设盲的资深作者建立的参考诊断作为标准,比较床旁与常规诊断的准确性。

诊断标准与关键数值

  • 常规超声平均诊断准确率84%,床旁超声74%(P<.001)。
  • 常规超声检测异常的敏感度85%、特异度83%;床旁超声敏感度75%、特异度68%。
  • 床旁超声的图像质量和诊断信心变异更大,这导致了其诊断准确率较低。
  • 当床旁与常规检查的图像质量和诊断信心相似时,两者准确率无差异。

临床应用与阅片要点

  • 原文结论指出床旁超声对基础、聚焦检查的准确性几乎与常规超声相当,差异归因于床旁超声图像质量变异更大。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the diagnostic accuracy of hand-held point-of-care (POC) versus conventional sonography in a general diagnostic setting with the intention to inform medical providers or clinicians on the rational use of POC ultrasound in resource limited settings.

METHODS: Over 3 months in 2010, 47 patients were prospectively enrolled at a single academic center to obtain 54 clinical conventional ultrasound examinations and 54 study-only POC ultrasound examinations. Indications were 48% abdominal, 26% retroperitoneal, and 24% obstetrical. Nine blinded readers (sonographers, residents, and attending radiologists) sequentially assigned diagnoses to POC and then conventional studies, yielding 476 interpreted study pairs. Diagnostic accuracy was obtained by comparing POC and conventional diagnoses to a reference diagnosis established by the unblinded, senior author. Analysis was stratified by study type, body mass index (BMI), diagnostic confidence, and image quality.

RESULTS: The mean diagnostic accuracy of conventional sonography was 84% compared with 74% for POC (P < .001). This difference was constant regardless of reader, exam type, or BMI. The sensitivity and specificity to detect abnormalities with conventional was 85 and 83%, compared with 75 and 68% for POC. The POC sonography demonstrated greater variability in image quality and diagnostic confidence, and this accounted for lower diagnostic accuracy. When image quality and diagnostic confidence were similar between POC and conventional examinations, there was no difference in accuracy.

CONCLUSIONS: Point-of-care was nearly as accurate as conventional sonography for basic, focused examinations. Observed differences in accuracy were attributed to greater variation in POC image quality.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Haider SJA, diFlorio-Alexander R, Lam DH, et al. Prospective Comparison of Diagnostic Accuracy Between Point-of-Care and Conventional Ultrasound in a General Diagnostic Department: Implications for Resource-Limited Settings. J Ultrasound Med. 2017. PMID: 28339133. doi:10.7863/ultra.16.06084