文献速递腹部外周血管介入USDSA

点剪切波弹性成像评估和监测失代偿期肝硬化患者门静脉压力变化

Point Shear Wave Elastography to Evaluate and Monitor Changing Portal Venous Pressure in Patients with Decompensated Cirrhosis.
PubMed 文献 · Ultrasound Med Biol · 2017-03-21

研究纳入67例前瞻性入组并接受经颈静脉肝内门体分流术(TIPS)和点剪切波弹性成像(pSWE)的失代偿期肝硬化患者,评估肝、脾硬度与门静脉压力(PVP)的相关性及剪切波速度变化(ΔSWV)与PVP变化(ΔPVP)的关系。结果显示脾硬度在TIPS前后均与PVP正相关(p<0.002),肝硬度与PVP无相关性;脾ΔSWV与ΔPVP强相关(r=0.871),诊断TIPS技术成功的ROC曲线下面积为0.869,ΔSWV截断值0.36 m/s时敏感度77%。

要点

  • 脾硬度在TIPS前后均与门静脉压力正相关,肝硬度与门静脉压力无相关性。
  • 脾剪切波速度变化与门静脉压力变化强相关(r=0.871)。
  • ΔSWV诊断TIPS技术成功的AUC为0.869,截断值0.36 m/s时敏感度77%。

核心结论

  • 脾硬度测量可用于失代偿期肝硬化患者门静脉压力的无创评估和监测。

研究设计与样本

  • 前瞻性入组67例接受TIPS和pSWE的失代偿期肝硬化患者,测量肝、脾剪切波速度(SWV)并与PVP进行Spearman秩相关分析,构建ROC曲线评估ΔSWV的诊断能力。

诊断标准与关键数值

  • 脾硬度与TIPS前、后PVP均呈正相关(p<0.002);脾ΔSWV与ΔPVP强相关(r=0.871);诊断TIPS技术成功的AUC为0.869,ΔSWV截断值0.36 m/s时敏感度77%。

临床应用与阅片要点

  • 作者认为脾硬度测量可用于失代偿期肝硬化患者门静脉压力的无创评估和监测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This study evaluated whether the stiffness of the liver and spleen, measured using the point shear wave elastography (pSWE) technique, correlates with portal venous pressure (PVP) and whether the result extends to estimate the diminishing change in PVP (ΔPVP) in patients with decompensated cirrhosis. We evaluated the data of 67 prospectively enrolled patients who underwent both transjugular intrahepatic portosystemic shunt (TIPS) and pSWE. The stiffness of liver and spleen were evaluated by measuring shear wave velocity (SWV) to determine the statistical correlation with PVP. We also analyzed whether change in SWV (ΔSWV) correlates with ΔPVP. The correlations were assessed with Spearman's rank correlation coefficients. Furthermore, receiver operating characteristic (ROC) curves were constructed to evaluate diagnostic capacity of ΔSWV. Spleen stiffness (SS) was positively correlated with PVP before and after TIPS (p < 0.002), although no correlation between liver stiffness and PVP was detected. A strong relationship between ΔSWV in SS and ΔPVP change in portal hypertension (r = 0.871) was also found in the overall population. The area under the ROC curve for the diagnosis of TIPS technical success was 0.869 and at a ΔSWV cut-off value of 0.36 m/s sensitivity was 77%. Measurement of SS can be used for non-invasive assessment and monitoring of PVP in patients with decompensated cirrhosis.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Han H, Yang J, Zhuge YZ, et al. Point Shear Wave Elastography to Evaluate and Monitor Changing Portal Venous Pressure in Patients with Decompensated Cirrhosis. Ultrasound Med Biol. 2017. PMID: 28335998. doi:10.1016/j.ultrasmedbio.2017.01.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。