定量超声、常规超声与MRI预测成人非酒精性脂肪性肝病组织学脂肪变分级的初步比较研究
前瞻性设计初步研究纳入61例组织学确诊的非酒精性脂肪性肝病患者,在肝活检100天内行定量超声(衰减系数、背向散射系数)、常规超声和MRI质子密度脂肪分数检查。常规超声分级准确率51.7%,衰减系数原始与交叉验证准确率分别为61.7%和55.0%,背向散射系数均为68.3%,MRI-PDFF分别为76.7%和71.3%。初步观察提示定量超声参数可能较常规超声更准确且观察者间一致性更高。
要点
- MRI-PDFF分级准确率最高(原始76.7%、交叉验证71.3%),背向散射系数次之(均68.3%)。
- 常规超声分级准确率仅51.7%,观察者间一致率53.3%(κ=0.61)。
- 衰减系数观察者间一致率90.0%(κ=0.87),背向散射系数71.7%(κ=0.82)。
核心结论
- 初步观察提示,定量超声参数在预测非酒精性脂肪性肝病肝脂肪变分级方面可能比常规超声更准确,且观察者间一致性更高。
研究设计与样本
- 前瞻性设计的初步研究,纳入61例组织学确诊的非酒精性脂肪性肝病患者,于2012年9月至2014年2月入组,在临床肝活检100天内行定量超声、常规超声和MRI检查。
关键影像表现/征象
- 定量超声参数包括衰减系数和背向散射系数,采用参考体模技术由两名分析者独立估计。
- 常规超声采用三点序数评分(1、2或3级)预测脂肪变分级,由两名放射科医师基于定量超声特征独立生成。
- PDFF采用基于化学位移的先进MRI技术估计。
诊断标准与关键数值
- 以组织学检查为参考标准进行ROC分析,确定衰减系数、背向散射系数和PDFF的最佳截断阈值。
- 常规超声分级准确率为51.7%。
- 衰减系数原始和交叉验证的脂肪变分级准确率分别为61.7%和55.0%。
- 背向散射系数原始和交叉验证的脂肪变分级准确率均为68.3%。
- MRI估计PDFF原始和交叉验证的脂肪变分级准确率分别为76.7%和71.3%。
临床应用与阅片要点
- 定量超声参数(衰减系数、背向散射系数)观察者间一致率分别为90.0%(κ=0.87)和71.7%(κ=0.82),高于常规超声的53.3%(κ=0.61),p<0.0001。
- 常规超声分级准确率51.7%,定量超声参数和MRI-PDFF分级准确率数值上更高。
局限性
- 原文标题标明为初步研究(Pilot)。
- 原文结论使用「初步观察提示」和「可能」等限定语气。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study is to explore the diagnostic performance of two investigational quantitative ultrasound (QUS) parameters, attenuation coefficient and backscatter coefficient, in comparison with conventional ultrasound (CUS) and MRI-estimated proton density fat fraction (PDFF) for predicting histology-confirmed steatosis grade in adults with nonalcoholic fatty liver disease (NAFLD).
SUBJECTS AND METHODS: In this prospectively designed pilot study, 61 adults with histology-confirmed NAFLD were enrolled from September 2012 to February 2014. Subjects underwent QUS, CUS, and MRI examinations within 100 days of clinical-care liver biopsy. QUS parameters (attenuation coefficient and backscatter coefficient) were estimated using a reference phantom technique by two analysts independently. Three-point ordinal CUS scores intended to predict steatosis grade (1, 2, or 3) were generated independently by two radiologists on the basis of QUS features. PDFF was estimated using an advanced chemical shift-based MRI technique. Using histologic examination as the reference standard, ROC analysis was performed. Optimal attenuation coefficient, backscatter coefficient, and PDFF cutoff thresholds were identified, and the accuracy of attenuation coefficient, backscatter coefficient, PDFF, and CUS to predict steatosis grade was determined. Interobserver agreement for attenuation coefficient, backscatter coefficient, and CUS was analyzed.
RESULTS: CUS had 51.7% grading accuracy. The raw and cross-validated steatosis grading accuracies were 61.7% and 55.0%, respectively, for attenuation coefficient, 68.3% and 68.3% for backscatter coefficient, and 76.7% and 71.3% for MRI-estimated PDFF. Interobserver agreements were 53.3% for CUS (κ = 0.61), 90.0% for attenuation coefficient (κ = 0.87), and 71.7% for backscatter coefficient (κ = 0.82) (p < 0.0001 for all).
CONCLUSION: Preliminary observations suggest that QUS parameters may be more accurate and provide higher interobserver agreement than CUS for predicting hepatic steatosis grade in patients with NAFLD.
引用
- Paige JS, Bernstein GS, Heba E, et al. A Pilot Comparative Study of Quantitative Ultrasound, Conventional Ultrasound, and MRI for Predicting Histology-Determined Steatosis Grade in Adult Nonalcoholic Fatty Liver Disease. AJR Am J Roentgenol. 2017. PMID: 28267360. doi:10.2214/AJR.16.16726
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。