文献速递腹部MR

3T下自旋回波回波平面成像与梯度回波磁共振弹性成像在钆塞酸二钠给药前后的比较

Comparison of spin-echo echoplanar imaging and gradient recalled echo-based MR elastography at 3 Tesla with and without gadoxetic acid administration.
PubMed 文献 · Eur Radiol · 2017-03-13

纳入84例患者在钆塞酸二钠给药前后分别行SE-EPI与GRE磁共振弹性成像,比较诊断肝硬化及高危食管静脉曲张的AUC。SE-EPI失败率显著低于GRE(1.19% vs. 10.71%),两者AUC无显著差异,给药前后肝硬度值无显著差异;作者认为SE-EPI可替代GRE,尤其适用于铁沉积患者。

要点

  • SE-EPI-MRE失败率1.19%显著低于GRE-MRE的10.71%(P=0.018)。
  • 诊断临床肝硬化AUC:SE-EPI 0.938 vs GRE 0.948(P=0.235),无显著差异。
  • 诊断高危食管静脉曲张AUC:SE-EPI 0.839 vs GRE 0.752(P=0.354),无显著差异。

核心结论

  • SE-EPI-MRE可替代GRE-MRE用于检测临床肝硬化及高危食管静脉曲张,且在铁沉积患者中尤其有用,失败率低于GRE-MRE。

研究设计与样本

  • 纳入84例患者在钆塞酸二钠给药前后分别行SE-EPI与GRE序列MRE,比较诊断临床肝硬化及高危食管静脉曲张的AUC,并分析T2*与MRE成功的关系及两序列间、给药前后肝硬度值的相关性。

诊断标准与关键数值

  • 诊断临床肝硬化AUC:SE-EPI-MRE 0.938 vs GRE-MRE 0.948(P=0.235)。
  • 诊断高危食管静脉曲张AUC:SE-EPI-MRE 0.839 vs GRE-MRE 0.752(P=0.354)。
  • MRE失败率:SE-EPI-MRE 1.19% vs GRE-MRE 10.71%(P=0.018)。
  • T2*升高与肝硬度测量成功概率较高相关(OR 1.426,P=0.004)。

临床应用与阅片要点

  • SE-EPI-MRE可替代GRE-MRE用于检测临床肝硬化及高危食管静脉曲张。
  • SE-EPI-MRE在铁沉积患者中尤其有用,失败率低于GRE-MRE。
  • 钆塞酸二钠给药不影响肝硬度测量,给药前后肝硬度值无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare spin-echo echoplanar imaging (SE-EPI) and gradient recalled echo (GRE) MR elastography (MRE) at 3 T with and without gadoxetic acid administration.

METHODS: We included 84 patients who underwent MRE before and after gadoxetic acid administration, each time using SE-EPI and GRE sequences. Diagnostic performance for predicting clinical liver cirrhosis and high-risk oesophageal varices was assessed using the area under the receiver-operating characteristic curve (AUC). The relationships between T2* and success of MRE, and correlations of liver stiffness (LS) values between the two sequences or before and after gadoxetic acid administration, were investigated.

RESULTS: SE-EPI-MRE resulted in a significantly lower failure rate than GRE-MRE (1.19% vs. 10.71%, P = 0.018). Increased T2* was related to higher probability of successful LS measurement (odds ratio, 1.426; P = 0.004). The AUC of SE-EPI-MRE was comparable to that of GRE-MRE for the detection of clinical liver cirrhosis (0.938 vs. 0.948, P = 0.235) and high-risk oesophageal varices (0.839 vs. 0.752, P = 0.354). LS values were not significantly different before and after gadoxetic acid administration.

CONCLUSION: SE-EPI-MRE can substitute for GRE-MRE for the detection of clinical liver cirrhosis and high-risk oesophageal varices. SE-EPI-MRE is particularly useful in patients with iron deposition, with lower failure rates than GRE-MRE.

KEY POINTS: • LS values are comparable between SE-EPI-MRE and GRE-MRE. • Administration of gadoxetic acid does not influence LS measurement. • The failure rate of SE-EPI-MRE is significantly lower than that of GRE-MRE.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim YS, Song JS, Kannengiesser S, et al. Comparison of spin-echo echoplanar imaging and gradient recalled echo-based MR elastography at 3 Tesla with and without gadoxetic acid administration. Eur Radiol. 2017. PMID: 28289936. doi:10.1007/s00330-017-4781-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。