文献速递腹部骨肌MR

定量腹部脂肪组织与大腿肌肉体积及肝脏质子密度脂肪分数:基于MR成像的半自动分析方法的可重复性与准确性

Quantifying Abdominal Adipose Tissue and Thigh Muscle Volume and Hepatic Proton Density Fat Fraction: Repeatability and Accuracy of an MR Imaging-based, Semiautomated Analysis Method.
PubMed 文献 · Radiology · 2017-03-09

这项前瞻性研究评估了一种商用MR成像半自动分析方法定量腹部脂肪组织、大腿肌肉体积和肝脏质子密度脂肪分数(PDFF)的可重复性与准确性;以人工法和MR波谱为参考标准,结果显示该方法具有高可重复性和准确性。

要点

  • 半自动MR方法定量腹部脂肪和大腿肌肉体积的组内相关系数为0.996-0.998,变异系数为1.5%-3.6%。
  • 肝脏MR成像PDFF的组内和组间检查组内相关系数≥0.994,变异系数≤7.3%。
  • 与参考标准回归分析中,PDFF斜率和截距接近等值线,决定系数R²为0.744-0.994。

核心结论

  • 这种基于MR成像的半自动方法在估计腹部脂肪组织、大腿肌肉体积和肝脏PDFF方面具有高可重复性和准确性。

研究设计与样本

  • 前瞻性研究,纳入20名受试者(18名女性;年龄范围25-76岁;体重指数范围19.3-43.9 kg/m²),采用三维T1加权双回波体线圈图像采集三次,以人工分割法和MR波谱为参考标准。

诊断标准与关键数值

  • 腹部脂肪和大腿肌肉体积:组内和组间检查组内相关系数为0.996-0.998,变异系数为1.5%-3.6%。
  • 肝脏MR成像PDFF:组内和组间检查组内相关系数≥0.994,变异系数≤7.3%。
  • 准确性回归分析:人工法与半自动法体积以及波谱法与MR成像PDFF的斜率和截距接近等值线,多变量分析决定系数R²为0.744-0.994。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To determine the repeatability and accuracy of a commercially available magnetic resonance (MR) imaging-based, semiautomated method to quantify abdominal adipose tissue and thigh muscle volume and hepatic proton density fat fraction (PDFF). Materials and Methods This prospective study was institutional review board- approved and HIPAA compliant. All subjects provided written informed consent. Inclusion criteria were age of 18 years or older and willingness to participate. The exclusion criterion was contraindication to MR imaging. Three-dimensional T1-weighted dual-echo body-coil images were acquired three times. Source images were reconstructed to generate water and calibrated fat images. Abdominal adipose tissue and thigh muscle were segmented, and their volumes were estimated by using a semiautomated method and, as a reference standard, a manual method. Hepatic PDFF was estimated by using a confounder-corrected chemical shift-encoded MR imaging method with hybrid complex-magnitude reconstruction and, as a reference standard, MR spectroscopy. Tissue volume and hepatic PDFF intra- and interexamination repeatability were assessed by using intraclass correlation and coefficient of variation analysis. Tissue volume and hepatic PDFF accuracy were assessed by means of linear regression with the respective reference standards. Results Adipose and thigh muscle tissue volumes of 20 subjects (18 women; age range, 25-76 years; body mass index range, 19.3-43.9 kg/m2) were estimated by using the semiautomated method. Intra- and interexamination intraclass correlation coefficients were 0.996-0.998 and coefficients of variation were 1.5%-3.6%. For hepatic MR imaging PDFF, intra- and interexamination intraclass correlation coefficients were greater than or equal to 0.994 and coefficients of variation were less than or equal to 7.3%. In the regression analyses of manual versus semiautomated volume and spectroscopy versus MR imaging, PDFF slopes and intercepts were close to the identity line, and correlations of determination at multivariate analysis (R2) ranged from 0.744 to 0.994. Conclusion This MR imaging-based, semiautomated method provides high repeatability and accuracy for estimating abdominal adipose tissue and thigh muscle volumes and hepatic PDFF. © RSNA, 2017.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Middleton MS, Haufe W, Hooker J, et al. Quantifying Abdominal Adipose Tissue and Thigh Muscle Volume and Hepatic Proton Density Fat Fraction: Repeatability and Accuracy of an MR Imaging-based, Semiautomated Analysis Method. Radiology. 2017. PMID: 28278002. doi:10.1148/radiol.2017160606

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。