文献速递腹部技术与安全US

瓦氏动作生理性减少肝静脉血流可降低肝脏硬度

Physiologic Reduction of Hepatic Venous Blood Flow by the Valsalva Maneuver Decreases Liver Stiffness.
PubMed 文献 · J Ultrasound Med · 2017-03-20

本研究在15名健康志愿者中,用7个谐波驱动频率(30-60 Hz)的时谐弹性成像测量右肝叶肝脏硬度,并用超声多普勒评估瓦氏动作前后门静脉和右肝静脉的血流变化。瓦氏动作使右肝静脉直径、血流量和峰值流速均下降,肝脏硬度在全部志愿者中平均降低约13%(从1.71±0.22 m/s降至1.48±0.22 m/s,P=.00006)。作者认为肝脏硬度对静脉血流改变敏感,弹性成像评估门静脉高压时需标准化呼吸条件。

要点

  • 瓦氏动作使右肝静脉直径从8.64±1.85 mm降至6.55±1.84 mm(P=.002)。
  • 瓦氏动作使肝脏硬度在全部志愿者中平均降低约13%,从1.71±0.22 m/s降至1.48±0.22 m/s(P=.00006)。
  • 肝脏硬度测量需标准化呼吸条件,以排除肝血流变化对弹性成像结果的影响。

核心结论

  • 肝脏硬度对静脉血流改变敏感,弹性成像评估门静脉高压时需标准化呼吸条件以排除肝血流变化的影响。

研究设计与样本

  • 在15名健康志愿者中,用7个谐波驱动频率(30-60 Hz)的时谐弹性成像测量右肝叶肝脏硬度,并用超声脉冲波多普勒速度、血管直径评估和血流量测量评估门静脉和右肝静脉的肝内静脉血流变化。

临床应用与阅片要点

  • 作者认为,使用弹性成像评估门静脉高压时,肝脏硬度对静脉血流改变敏感具有临床重要性;准确的肝脏硬度测量需要标准化呼吸条件,以排除肝血流变化对弹性成像结果的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Liver stiffness increases after intake of food or water, suggesting that hepatic venous blood flow affects the results of elastographic measurements. This study investigated the correlation between in vivo liver stiffness and hepatic blood flow using the Valsalva maneuver for reducing intrahepatic venous blood flow.

METHODS: Intrahepatic changes in venous blood flow were assessed by sonography based on the pulsed wave Doppler velocity, vessel diameter assessment, and blood flow volume measurements in the portal vein and right hepatic vein. Time-harmonic elastography at 7 harmonic driving frequencies (30-60 Hz) was used to measure liver stiffness in the right liver lobe of 15 healthy volunteers.

RESULTS: The right hepatic vein diameter, flow volume, and peak pulsed wave velocity decreased during the Valsalva maneuver from mean ± SD values of 8.64 ± 1.85 to 6.55 ± 1.84 mm (P = .002), 0.53 ± 0.23 to 0.37 ± 0.26 L/min (P = .037), and 22.14 ± 4.87 to 17.38 ± 5.41 cm/s (P = .01), respectively. This maneuver decreased liver stiffness in all volunteers by a mean of approximately 13% from 1.71 ± 0.22 to 1.48 ± 0.22 m/s (P = .00006).

CONCLUSIONS: Our results demonstrate that liver stiffness is sensitive to altered venous blood flow, which is of clinical importance when using elastography for evaluation of portal hypertension. Furthermore, our results indicate that accurate measurement of liver stiffness requires standardized breathing conditions to rule out effects of changes in hepatic blood flow on elastographic findings.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ipek-Ugay S, Tzschätzsch H, Braun J, et al. Physiologic Reduction of Hepatic Venous Blood Flow by the Valsalva Maneuver Decreases Liver Stiffness. J Ultrasound Med. 2017. PMID: 28319252. doi:10.7863/ultra.16.07046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。