文献速递技术与安全腹部US

卢旺达医院床旁超声的使用、准确性及其对临床决策的影响

Point-of-Care Ultrasound Use, Accuracy, and Impact on Clinical Decision Making in Rwanda Hospitals.
PubMed 文献 · J Ultrasound Med · 2017-03-04

对卢旺达医院医生开展床旁超声培训后,医生记录1158次超声检查,其中590次(50.9%)有匹配图像可供复核;受训者检查总体敏感度94%、特异度98%,平均图像质量评分为2.36(95%CI 2.28-2.44),床旁超声最常改变用药(42.4%)和处置(30%)。

要点

  • 受训者完成的床旁超声总体敏感度94%、特异度98%。
  • 平均图像质量评分为2.36(95%CI 2.28-2.44)。
  • 床旁超声最常改变用药(42.4%)和患者处置(30%)。

核心结论

  • 在低资源地区开展床旁超声培训干预后,长期随访中获得了大量诊断质量的检查,且床旁超声常规改变了临床决策。

研究设计与样本

  • 对卢旺达医院医生开展床旁超声培训,医生随后使用床旁超声并记录所见、判读及对患者管理的影响,数据收集6个月,对受训者检查进行图像质量和准确性复核。

诊断标准与关键数值

  • 受训者完成检查的总体敏感度为94%、特异度为98%;平均图像质量评分为2.36(95%CI 2.28-2.44)。

临床应用与阅片要点

  • 床旁超声最常改变用药(42.4%)和患者处置(30%);游离液体腹部超声是最常执行的应用。

局限性

  • 590项检查(50.9%)有匹配图像和判读可供复核,其余检查未能复核。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Few studies of point-of-care ultrasound training and use in low resource settings have reported the impact of examinations on clinical management or the longer-term quality of trainee-performed studies. We characterized the long-term effect of a point-of-care ultrasound program on clinical decision making, and evaluated the quality of clinician-performed ultrasound studies.

METHODS: We conducted point-of-care ultrasound training for physicians from Rwandan hospitals. Physicians then used point-of-care ultrasound and recorded their findings, interpretation, and effects on patient management. Data were collected for 6 months. Trainee studies were reviewed for image quality and accuracy.

RESULTS: Fifteen participants documented 1158 ultrasounds; 590 studies (50.9%) had matched images and interpretations for review. Abdominal ultrasound for free fluid was the most frequently performed application. The mean image quality score was 2.36 (95% confidence interval, 2.28-2.44). Overall sensitivity and specificity for trainee-performed examinations was 94 and 98%. Point-of-care ultrasound use most commonly changed medications administered (42.4%) and disposition (30%).

CONCLUSIONS: A point-of-care ultrasound training intervention in a low-resource setting resulted in high numbers of diagnostic-quality studies over long-term follow-up. Ultrasound use routinely changed clinical decision making.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Henwood PC, Mackenzie DC, Liteplo AS, et al. Point-of-Care Ultrasound Use, Accuracy, and Impact on Clinical Decision Making in Rwanda Hospitals. J Ultrasound Med. 2017. PMID: 28258591. doi:10.7863/ultra.16.05073

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。