预测右型大动脉转位胎儿是否需要Rashkind手术的新方法

New method to predict need for Rashkind procedure in fetuses with dextro-transposition of the great arteries.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-01-01

该回顾性双中心研究纳入2006至2013年产前诊断的98例右型大动脉转位胎儿,最终51例符合标准,比较出生后24小时内需行Rashkind手术组(29例)与未行该手术组(22例)。结果显示需手术组肺静脉最大流速显著更高(47.62±7.48 vs 32.21±5.47 cm/s,P<0.001),41 cm/s阈值特异度和阳性预测值均为100%,敏感度82%、阴性预测值86%;卵圆孔瓣平坦在需手术组占52%。

要点

  • 肺静脉最大流速41 cm/s预测生后24小时内需Rashkind手术,特异度100%、阳性预测值100%。
  • 需手术组肺静脉最大流速显著高于未手术组(47.62±7.48 vs 32.21±5.47 cm/s,P<0.001)。
  • 卵圆孔瓣平坦见于52%的需Rashkind手术胎儿,两组卵圆孔直径及血流速度无差异。

核心结论

  • 在右型大动脉转位胎儿中,产前超声发现肺静脉血流速度增高和卵圆孔瓣平坦与出生后24小时内需行Rashkind手术相关,这些超声心动图特征可用于产前预测分娩后是否需要该手术。

研究设计与样本

  • 回顾性研究,2006至2013年两个欧洲中心产前诊断的单胎妊娠右型大动脉转位98例,排除标准包括分娩前3周内无胎儿超声心动图(n=18)、37周前分娩(n=6)、肺静脉最大流速测量不当或缺失(n=10)、缺乏新生儿随访数据(n=9)、出生24小时后行Rashkind手术(n=4),最终51例纳入分析。

关键影像表现/征象

  • 需Rashkind手术组肺静脉最大流速显著高于未手术组(47.62±7.48 vs 32.21±5.47 cm/s,P<0.001)。
  • 卵圆孔瓣平坦在需Rashkind手术组占52%。
  • 两组胎儿心脏大小(心脏面积/胸面积比)、左右心室比例失调率、卵圆孔直径及卵圆孔最大血流速度产前均无差异。

诊断标准与关键数值

  • 肺静脉最大流速41 cm/s为阈值预测出生后24小时内需Rashkind手术,特异度100%、阳性预测值100%、敏感度82%、阴性预测值86%。

临床应用与阅片要点

  • 产前超声测量肺静脉最大流速并观察卵圆孔瓣形态,有助于识别出生后24小时内需Rashkind手术的右型大动脉转位胎儿。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Prenatal congenital heart disease classification systems distinguish between critical dextro-transposition of the great arteries (d-TGA) with restriction of the foramen ovale (FO) (which requires a Rashkind procedure within the first 24 h following delivery) and d-TGA for which surgery is planned (after prostaglandin perfusion or Rashkind procedure later than 24 h after delivery). However, current prenatal diagnostic criteria for postnatal FO restriction in d-TGA are inadequate, resulting in a high false-negative rate. We aimed to identify echocardiographic features to predict the urgent need for Rashkind procedure.

METHODS: We identified retrospectively 98 patients with singleton pregnancy diagnosed prenatally with fetal d-TGA at two European centers from 2006 to 2013. Two groups were compared: (1) those in whom the Rashkind procedure was performed within the first 24 h postnatally; and (2) those who did not undergo a Rashkind procedure before cardiac surgery. Exclusion criteria were: (1) no fetal echocardiography within 3 weeks prior to delivery (n = 18); (2) delivery before 37 weeks of gestation (n = 6); (3) improper or lack of measurement of pulmonary vein maximum flow velocity (n = 10); (4) lack of neonatal follow-up data (n = 9); (5) Rashkind procedure performed more than 24 h after delivery (n = 4).

RESULTS: Fifty-one patients met the inclusion criteria: 29 who underwent the Rashkind procedure and 22 who did not. There were no differences between these two study groups in terms of maternal age, gestational age at time of fetal echocardiography, fetal biometric measurements, estimated fetal weight, rate of Cesarean delivery, newborn weight or Apgar score at 1 min. There were also no differences during prenatal life between the two groups in terms of fetal cardiac size (heart area/chest area ratio), rate of disproportion between left and right ventricle, FO diameter and maximum velocity of flow through the FO. However, the pulmonary vein maximum velocity was significantly higher in the group requiring a Rashkind procedure (47.62 ± 7.48 vs 32.21 ± 5.47 cm/s; P < 0.001). The cut-off value of 41 cm/s provided maximum specificity (100%) and positive predictive value (100%) at only a slight cost of sensitivity (82%) and NPV (86%). The prenatal appearance of the FO also differed between the groups, the FO valve being flat in 52% of those requiring a Rashkind procedure.

CONCLUSIONS: In fetuses with d-TGA, prenatal sonographic findings of increased pulmonary venous blood flow and flattened FO valve were associated with the need for a Rashkind procedure within the first 24 h postnatally; these echocardiographic features could be used to predict prenatally a need for the procedure following delivery. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Słodki M, Axt-Fliedner R, Zych-Krekora K, et al. New method to predict need for Rashkind procedure in fetuses with dextro-transposition of the great arteries. Ultrasound Obstet Gynecol. 2018. PMID: 28295809. doi:10.1002/uog.17469

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。