心脏磁共振组织追踪评估Ebstein畸形患者左心室形变
本研究纳入32例Ebstein畸形患者和30例对照行心脏磁共振检查,测量左心室功能、尺寸及组织追踪参数。结果显示Ebstein畸形组整体应变参数均显著降低,且射血分数减低组整体径向和环向峰值应变更低;左心室应变可较左心室射血分数更早、更全面地反映左心室功能障碍。
要点
- Ebstein畸形患者左心室整体径向、环向和纵向峰值应变均较对照显著降低。
- 左心室射血分数减低的Ebstein畸形患者整体径向和环向峰值应变低于射血分数保留者。
- Ebstein畸形患者左心室节段应变异常主要累及基底段和中间段。
核心结论
- 左心室应变较左心室射血分数能更早、更全面地检测Ebstein畸形患者的左心室功能障碍,可能作为评估Ebstein畸形的补充诊断手段。
研究设计与样本
- 研究纳入32例Ebstein畸形患者和30例对照行心脏磁共振检查,测量左心室功能、尺寸和组织追踪参数(整体及节段径向、环向和纵向峰值应变)以及右心室尺寸。
- 按左心室射血分数将患者分为射血分数保留组(≥55%)和射血分数减低组(<55%),与对照组比较左心室应变参数。
关键影像表现/征象
- Ebstein畸形组整体应变参数均较对照组显著降低(均P<0.05)。
- Ebstein畸形患者节段应变异常主要累及基底段和中间段。
诊断标准与关键数值
- 射血分数减低组整体径向峰值应变28.64% vs. 射血分数保留组37.39%(P<0.05)。
- 射血分数减低组整体环向峰值应变-8.20% vs. 射血分数保留组-17.89%(P<0.05)。
- 右心室舒张末期内径与左心室舒张末期内径比值(RVEDD/LVEDD指数)与整体环向峰值应变相关(r=0.508),与纵向峰值应变相关(r=0.474)。
- 径向峰值应变与左心室射血分数相关(r=0.465)。
- 观察者内和观察者间组内相关系数分别为0.797-0.904和0.701-0.896。
临床应用与阅片要点
- 作者认为左心室应变可作为评估Ebstein畸形的补充诊断手段。
- 阅片时可关注Ebstein畸形患者左心室基底段和中间段的节段应变异常。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this study was to clarify the feasibility of myocardial strain using cardiovascular magnetic resonance (CMR) for the evaluation of left ventricular (LV) deformation in patients with Ebstein's anomaly (EA).
MATERIALS AND METHODS: We recruited 32 patients with EA and 30 controls for CMR examination and measured LV function, dimension and tissue tracking parameters (the global and regional radial, circumferential and longitudinal peak strain), together with the right ventricle (RV) dimension. LV strain parameters were compared among the controls, patients with preserved LV ejection fraction (LVEF; ≥55%), and patients with reduced LVEF (<55%). Pearson's correlation was used to evaluate relationships between tissue tracking parameters with the RVEDD/LVEDD index and LVEF. An ROC analysis was also performed to determine whether the cut-off values for PS could be used to differentiate LV dysfunction between patients with EA and controls. The intraclass correlation coefficient (ICC) was used to assess the inter- and intra-observer variability.
RESULTS: The global strain parameters all decreased significantly in the EA group compared with the control group (all P<0.05). Furthermore, the global radial and circumferential peak strain (PS) were obviously even lower in the reduced LVEF group than the strain measured in preserved LVEF groups (28.64% vs. 37.39%, p<0.05; and -8.20% vs. -17.89%; p<0.05; respectively). The regional strain abnormalities in EA patients were mainly involved in basal and middle segments. The results also demonstrated a significant correlation between the ratio of the RV end-diastolic dimension to the LV end-diastolic dimension (RVEDD/LVEDD index) with the global circumferential PS (r=0.508) and the longitudinal PS (r=0.474), as well as a good correlation between radial PS and LVEF (r=0.465). The ICCs for intra- and inter-observer variability were 0.797-0.904 and 0.701-0.896.
CONCLUSIONS: LV strain serves an earlier and more comprehensive measurement of LV dysfunction than LVEF in EA, which could potentially be included as a supplementary diagnostic procedure in the evaluation of EA.
引用
- Liu X, Zhang Q, Yang ZG, et al. Assessment of left ventricular deformation in patients with Ebstein's anomaly by cardiac magnetic resonance tissue tracking. Eur J Radiol. 2017. PMID: 28267539. doi:10.1016/j.ejrad.2017.01.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。