文献速递心血管PET

CZT技术心肌灌注成像的诊断准确性:与有创冠状动脉造影比较的系统综述与Meta分析

Diagnostic Accuracy of Myocardial Perfusion Imaging With CZT Technology: Systemic Review and Meta-Analysis of Comparison With Invasive Coronary Angiography.
PubMed 文献 · JACC Cardiovasc Imaging · 2017-03-15

该系统综述与Meta分析纳入16项研究共2092例患者,比较CZT技术负荷心肌灌注成像与有创冠状动脉造影诊断阻塞性冠心病的准确性。CZT-MPI敏感度为0.84,特异度为0.69,诊断比值比为11.93。作者结论认为CZT-MPI对造影显著冠心病具有满意敏感度,但特异度欠佳,需进一步开发与研究。

要点

  • CZT-MPI诊断造影显著冠心病敏感度0.84(95%CI 0.78–0.89),特异度0.69(95%CI 0.62–0.76)。
  • 阳性似然比2.73(95%CI 2.21–3.39),阴性似然比0.24(95%CI 0.17–0.31),诊断比值比11.93(95%CI 7.84–17.42)。
  • D-SPECT与Discovery相机诊断准确性相似(p=0.711),小样本研究未影响结果(p=0.573)。

核心结论

  • CZT-MPI对造影显著冠心病具有满意敏感度,但特异度欠佳,需进一步开发与研究。

研究设计与样本

  • 系统综述与Meta分析,共纳入16项比较CZT-MPI与有创冠状动脉造影的临床研究(N=2,092);采用固定效应与随机效应模型计算诊断准确性,报告点估计值及95%CI。

诊断标准与关键数值

  • CZT-MPI诊断造影显著冠心病的敏感度为0.84(95%CI 0.78–0.89)。
  • CZT-MPI诊断造影显著冠心病的特异度为0.69(95%CI 0.62–0.76)。
  • 阳性似然比2.73(95%CI 2.21–3.39),阴性似然比0.24(95%CI 0.17–0.31),诊断比值比11.93(95%CI 7.84–17.42)。
  • 亚组与Meta回归分析显示D-SPECT与Discovery相机诊断准确性相似(p=0.711),小样本研究未影响诊断准确性(p=0.573)。

临床应用与阅片要点

  • 作者结论认为CZT-MPI对造影显著冠心病具有满意敏感度,但特异度欠佳,需进一步开发与研究。

局限性

  • 原文结论指出CZT-MPI特异度欠佳,需进一步开发与研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study sought to summarize the evidence on stress myocardial perfusion imaging (MPI) using cadmium-zinc-telluride (CZT) technology for the diagnosis of obstructive coronary artery disease (CAD). The CZT cameras are newly introduced, and comparative data with the conventional Anger technology (Anger-MPI) are lacking.

BACKGROUND: The diagnostic accuracy of Anger-MPI for detection of angiographically significant CAD is well established; however, less evidence is available on the diagnostic accuracy of CZT-MPI.

METHODS: Clinical studies comparing CZT-MPI and invasive coronary angiography were systematically searched and abstracted. Calculations of diagnostic accuracy, including sensitivity, specificity, likelihood ratios, and diagnostic odds ratio, were obtained with fixed and random effects, reporting point estimates and 95% confidence intervals.

RESULTS: Based on our search, a total of 16 studies (N = 2,092) were included. The sensitivity of CZT-MPI was 0.84 (95% confidence interval [CI]: 0.78 to 0.89), whereas the specificity of 0.69 (95% CI: 0.62 to 0.76) was significantly reduced. The positive likelihood ratio was 2.73 (95% CI: 2.21 to 3.39), the negative likelihood ratio was 0.24 (95% CI: 0.17 to 0.31), and the diagnostic odds ratio was 11.93 (95% CI: 7.84 to 17.42). At subgroup and meta-regression analyses, the diagnostic accuracy between D-SPECT and Discovery cameras was similar (p = 0.711) and not impacted upon by smaller sample size studies (p = 0.573).

CONCLUSIONS: CZT-MPI has satisfactory sensitivity for angiographically significant CAD, but its suboptimal specificity warrants further development and research.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Nudi F, Iskandrian AE, Schillaci O, et al. Diagnostic Accuracy of Myocardial Perfusion Imaging With CZT Technology: Systemic Review and Meta-Analysis of Comparison With Invasive Coronary Angiography. JACC Cardiovasc Imaging. 2017. PMID: 28330657. doi:10.1016/j.jcmg.2016.10.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。