应用心脏CT评估主动脉-肺动脉窦连合对齐不良以指导动脉调转术:与经胸超声心动图比较
37例完全性大动脉转位患儿中,以手术所见为参考,心脏CT诊断半月瓣连合对齐不良的敏感度91.7%、特异度87.0%、准确率88.6%,均高于超声心动图的75.0%、78.3%、77.1%,但差异无统计学意义(P>0.05);手术证实对齐不良组更多需要改良冠状动脉移植技术(11/13 vs 11/24,P=0.03)。
要点
- 心脏CT与超声心动图均可用于评估完全性大动脉转位患儿的半月瓣连合对齐不良。
- 手术证实对齐不良组需要改良冠状动脉移植技术的比例高于对齐组(11/13 vs 11/24,P=0.03)。
- 心脏CT诊断对齐不良的敏感度、特异度、准确率数值上高于超声心动图,但差异无统计学意义(P>0.05)。
核心结论
- 心脏CT和超声心动图似乎可用于评估完全性大动脉转位患者半月瓣的连合对齐不良,此类患者在接受动脉调转术时常需要改良冠状动脉移植技术。
研究设计与样本
- 对37例(35例男孩;中位年龄8天,范围3-80天)具有三叶半月瓣并接受动脉调转术的完全性大动脉转位患者,其心脏CT(n=37)和超声心动图(n=35)评估主动脉-肺动脉窦连合旋转程度,以手术所见为参考在35例中比较两种方法识别连合对齐不良,并评估心脏CT测量的半月瓣高度差对识别的影响及对齐不良对冠状动脉移植技术的影响。
诊断标准与关键数值
- 以手术所见为参考,心脏CT诊断连合对齐不良的敏感度91.7%、特异度87.0%、准确率88.6%。
- 超声心动图诊断连合对齐不良的敏感度75.0%、特异度78.3%、准确率77.1%。
- 心脏CT与超声心动图的敏感度、特异度、准确率差异无统计学意义(P>0.05)。
- 手术所见半月瓣连合对齐者24例,对齐不良者13例。
- 心脏CT测量的半月瓣高度差不影响心脏CT和超声心动图对对齐不良的识别。
临床应用与阅片要点
- 手术证实连合对齐不良组需要改良冠状动脉移植技术的比例高于对齐组(11/13 vs 11/24,P=0.03)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: There are limited data regarding the influence of commissural malalignment of the aortic-pulmonary sinus on the arterial switch operation.
OBJECTIVE: To compare diagnostic accuracy between cardiac CT and echocardiography for evaluating commissural malalignment of aortic-pulmonary sinus in children with complete transposition of the great arteries and to seek potential clinical implication of commissural malalignment on the arterial switch operation.
MATERIALS AND METHODS: In 37 patients (35 boys; median age: 8 days, range: 3-80 days) with complete transposition of the great arteries who had tricuspid semilunar valves and underwent an arterial switch operation, the degree of the commissural rotation of the aortic-pulmonary sinus was assessed on cardiac CT (n=37) and echocardiography (n=35). With surgical finding as a reference, cardiac CT was compared with echocardiography in identifying commissural malalignment in 35 patients. The influence of the height difference between the semilunar valves measured by cardiac CT on the identification of commissural malalignment with cardiac CT and echocardiography was evaluated. The impact of commissural malalignment on coronary transfer techniques was evaluated.
RESULTS: In operative findings, the commissures of the semilunar valves were aligned in 24 patients and malaligned in 13. With surgical findings as a reference, cardiac CT showed higher, but not statistically significant (P>0.05), sensitivity (91.7% vs. 75.0%), specificity (87.0% vs. 78.3%) and accuracy (88.6% vs. 77.1%) for the diagnosis of the malalignment than echocardiography. The measured height difference between the semilunar valves did not affect the identification of the malalignment with cardiac CT and echocardiography. The surgical malalignment group showed a higher requirement of modified coronary transfer techniques than the surgical aligned group (11/13 vs. 11/24, P=0.03).
CONCLUSION: Cardiac CT and echocardiography appear useful for evaluating commissural malalignment of the semilunar valves in patients with complete transposition of the great arteries frequently requiring modified coronary transfer techniques at during an arterial switch operation.
引用
- Bang JH, Park JJ, Goo HW, et al. Evaluation of commissural malalignment of aortic-pulmonary sinus using cardiac CT for arterial switch operation: comparison with transthoracic echocardiography. Pediatr Radiol. 2017. PMID: 28243677. doi:10.1007/s00247-017-3786-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。