住院医师使用口袋式成像设备进行床旁腹部超声的可行性与诊断准确性
在挪威Levanger医院,6名超声经验有限的住院医师使用口袋式成像设备对199例急诊入院患者进行肝、胆囊、肾和腹主动脉床旁超声检查,并与放射科参考影像对比。肾和肝成像可行性分别为85%和82%,胆囊79%,腹主动脉50%;检测器官病变的敏感度为54%至74%,主动脉内径评估相关性中等(r=0.38)。作者认为该检查可能有助于早期发现腹部病变,但准确性不足以排除腹部器官病变。
要点
- 住院医师使用口袋式设备对肾、肝、胆囊、腹主动脉的成像可行性分别为85%、82%、79%、50%。
- 检测器官病变的敏感度范围为54%(95%CI 29-77%)至74%(95%CI 51-88%)。
- 主动脉内径评估与参考影像呈中等相关(r=0.38),准确性有限。
核心结论
- 经验有限的住院医师使用口袋式成像设备进行床旁腹部超声可能有助于早期发现腹部病变,但准确性不足以排除腹部器官病变。
研究设计与样本
- 前瞻性连续纳入研究,共199例急诊入院患者,在挪威非大学附属Levanger医院内科于2011年4月4日至6月23日期间纳入;6名随机抽取的住院医师在入院时使用口袋式成像设备检查肝、胆囊、肾和腹主动脉,参考影像由放射科完成和/或判读。
诊断标准与关键数值
- 住院医师使用口袋式设备检测器官病变的敏感度范围为54%(95%CI 29-77%)至74%(95%CI 51-88%);肾、肝、胆囊、腹主动脉的成像可行性分别为85%、82%、79%、50%;主动脉内径评估与参考影像的相关系数r=0.38。
临床应用与阅片要点
- 作者认为口袋式设备床旁超声可能有助于早期发现腹部病变,但准确性不足以排除腹部器官病变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: We aimed to study the feasibility and diagnostic performance of bedside ultrasound by examination of the liver, gallbladder, kidneys, and abdominal aorta performed by medical residents with limited experience in ultrasound, on emergency admissions using pocket-sized imaging devices (PSIDs).
METHODS: A total of 199 patients admitted acutely to the medical department at the non-university Levanger Hospital, Norway, during the period from April 4 to June 23, 2011, were consecutively included. Six medical residents, selected by drawing, examined these patients with a PSID at admission. Reference imaging was performed and/or judged at the Department of Radiology.
RESULTS: Each resident performed a median of 28 examinations (interquartile range 24-46). Imaging of the kidneys and liver were feasible in 85 and 82% of the cases, and the corresponding values for the gallbladder and abdominal aorta were 79 and 50%, respectively. The sensitivity of medical residents to detect organ pathology with the aid of PSID, ranged between 54% (95% confidence interval [CI]: 29-77%) and 74% (95% CI: 51-88%). Assessment of the aortic dimension showed moderate correlation, with r = 0.38.
CONCLUSIONS: Examination by PSID by inexperienced residents may allow for early detection of abdominal pathology, but do not appear to be accurate enough to rule out pathology in the abdominal organs.
引用
- Kjesbu IE, Laursen CB, Graven T, et al. Feasibility and Diagnostic Accuracy of Point-of-Care Abdominal Sonography by Pocket-Sized Imaging Devices, Performed by Medical Residents. J Ultrasound Med. 2017. PMID: 28244145. doi:10.7863/ultra.16.05077
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。