文献速递妇产影像儿科影像US

电子时空影像相关技术提高胎儿四维超声心动图检查效率

Electronic spatiotemporal image correlation improves four-dimensional fetal echocardiography.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-02-07

一项随机对照试验纳入100例孕中期超声正常的孕妇,比较电子时空影像相关技术(eSTIC)与常规STIC获取四维胎儿心脏容积的诊断质量。eSTIC组获得最佳或满意诊断质量的比率高于常规STIC组(94% vs 76%,P < 0.0001)。eSTIC获取失败均因胎儿体位不佳。

要点

  • eSTIC组获取最佳或满意诊断质量容积的比例为94%,高于常规STIC组的76%(P < 0.0001)。
  • eSTIC获取失败均因胎儿体位不佳,而非技术本身。
  • 在本研究操作者手中,eSTIC可在标准胎儿解剖检查时限内,于超过90%的病例获得可供离线详细评估的最佳或满意容积。

核心结论

  • 与常规机械探头相比,电子四维探头有助于获取孕中期胎儿心脏超声容积;在本研究操作者手中,超过90%的病例可在标准胎儿解剖检查时限内获得最佳或满意诊断质量的eSTIC容积。

研究设计与样本

  • 随机对照试验,纳入100例孕中期超声正常的孕妇;一半病例使用常规机械四维探头获取STIC容积,另一半使用电子四维探头获取eSTIC容积;检查限制在标准胎儿解剖检查时限内,最多尝试两次获取四维心脏容积;数据集存储于计算机后离线分析,按能否完成扩展基础心脏检查(包括获取三血管气管切面及矢状面清晰重建主动脉弓和动脉导管弓)分为最佳、满意或不合格。

关键影像表现/征象

  • eSTIC容积数据集获得最佳或满意诊断质量的比例高于常规STIC(94% vs 76%,P < 0.0001)。
  • 未能获得足够质量eSTIC容积的病例均因胎儿体位不佳。

诊断标准与关键数值

  • 诊断质量分级依据能否完成扩展基础心脏检查,包括获取三血管气管切面及矢状面清晰重建主动脉弓和动脉导管弓,分为最佳、满意或不合格。
  • eSTIC组最佳或满意诊断质量比例为94%,常规STIC组为76%(P < 0.0001)。

临床应用与阅片要点

  • 在本研究操作者手中,eSTIC可在标准胎儿解剖检查时限内,于超过90%的病例获得可供离线详细评估胎儿心脏的最佳或满意诊断质量容积。
  • eSTIC获取失败均因胎儿体位不佳。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the efficiency of electronic spatiotemporal image correlation (eSTIC) with that of conventional STIC to acquire four-dimensional (4D) fetal cardiac volumes of diagnostic quality.

METHODS: This was a randomized controlled trial of 100 patients in mid-gestation with normal sonograms. In half of the cases, STIC volumes of the fetal heart were obtained with a conventional mechanical 4D probe and in the remaining cases eSTIC volumes were obtained with an electronic 4D probe. Examinations were kept within the timeframe allotted for a standard examination of fetal anatomy, and a maximum of two attempts were made at obtaining a 4D cardiac volume. Datasets were stored on a computer and subsequently analyzed and categorized as being of optimal, satisfactory or inadequate quality, depending on whether or not it was possible to perform an extended basic cardiac examination, including obtaining a three vessels and trachea view, as well as a clear reconstruction of both the aortic and ductal arches in the sagittal plane.

RESULTS: The eSTIC volume datasets were more frequently of optimal or satisfactory diagnostic quality compared with conventional STIC (94% vs 76%, P < 0.0001). Failure to obtain an eSTIC volume of adequate quality was in all cases the consequence of an unfavorable position of the fetus.

CONCLUSIONS: Compared with a standard mechanical probe, the electronic 4D probe facilitates acquisition of sonographic cardiac volumes in mid-trimester fetuses. In our hands, eSTIC volumes of optimal or satisfactory diagnostic quality, allowing a detailed offline evaluation of the fetal heart, were obtained in more than 90% of cases within the time frame of a standard examination of fetal anatomy. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Guasina F, Bellussi F, Morganelli G, et al. Electronic spatiotemporal image correlation improves four-dimensional fetal echocardiography. Ultrasound Obstet Gynecol. 2018. PMID: 28337810. doi:10.1002/uog.17474

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。