自由呼吸高螺距80kVp双源CT在儿童胸部检查中的图像质量、运动伪影及辐射剂量研究

Free-breathing high-pitch 80kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose.
PubMed 文献 · Eur J Radiol · 2017-02-06

本研究纳入87例连续儿童患者,随机分配接受自由呼吸高螺距(螺距3.2)80kVp双源CT联合ADMIRE迭代重建(31例)或标准螺距(螺距1.2)单源CT(56例)。双源CT联合ADMIRE的图像噪声和信噪比与单源CT相当,运动伪影显著减少,总体图像质量最高,且中位SSDE(0.82mGy vs 0.92mGy)和中位有效剂量(0.4mSv vs 0.48mSv)均低于单源CT。

要点

  • 自由呼吸高螺距双源CT联合ADMIRE可显著减少儿童胸部CT的运动伪影并提高总体图像质量。
  • 双源CT联合ADMIRE的噪声和信噪比与单源CT相当,而双源CT联合FBP的噪声和信噪比劣于单源CT。
  • 双源CT的中位SSDE和有效剂量均低于单源CT(0.82mGy vs 0.92mGy;0.4mSv vs 0.48mSv)。

核心结论

  • 自由呼吸高螺距80kVp胸部双源CT联合ADMIRE可减少运动伪影、提高图像质量,同时降低儿童患者的辐射暴露。

研究设计与样本

  • 经机构审查委员会批准的前瞻性随机对照研究,纳入87例连续儿童患者(平均年龄9.1±4.9岁),随机分入双源CT组(31例,螺距3.2,192层)或单源CT组(56例,螺距1.2,128层),两组管电压均为80kVp、参考管电流均为74mAs。

关键影像表现/征象

  • 运动伪影以膈肌和心脏边界重影测量,双源CT较单源CT显著减少(p=0.001)。
  • 双源CT联合ADMIRE的总体图像质量评分最高(p<0.0001)。
  • 双源CT联合FBP的图像噪声和信噪比结果劣于单源CT(p<0.01),而双源CT联合ADMIRE与单源CT相当(p>0.64)。

诊断标准与关键数值

  • 图像噪声和信噪比取自胸大肌和胸主动脉的测量计算。
  • 运动伪影以膈肌和心脏边界重影测量,并由两名盲法阅片者按5分制评分总体图像质量和运动伪影存在情况。
  • 辐射剂量以中位SSDE和有效剂量表示:双源CT组中位SSDE 0.82mGy vs 单源CT组0.92mGy(p<0.02);双源CT组中位有效剂量0.4mSv vs 单源CT组0.48mSv(p=0.02)。

临床应用与阅片要点

  • 对自由呼吸、未镇静的儿童胸部CT,采用高螺距双源CT联合ADMIRE可在不增加图像噪声的前提下减少运动伪影并降低辐射剂量。
  • 双源CT重建需联合ADMIRE迭代算法,若采用FBP则图像噪声和信噪比劣于单源CT。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT).

MATERIALS AND METHODS: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1±4.9years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n=31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n=56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated.

RESULTS: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p>0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p<0.01). Motion artifacts were reduced significantly (p=0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p<0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82mGy vs. 0.92mGy, p<0.02; median ED: 0.4 mSv vs. 0.48mSv, p=0.02).

CONCLUSIONS: High-pitch 80kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation.