文献速递胸部CT

CT上表现为≤30 mm实性结节的肺腺癌大小测量与T分期:影像-病理对照研究

Size Measurement and T-staging of Lung Adenocarcinomas Manifesting as Solid Nodules ≤30 mm on CT: Radiology-Pathology Correlation.
PubMed 文献 · Acad Radiol · 2017-02-28

本研究纳入274例经手术切除的影像学实性肺腺癌,比较CT长轴径与平均径测量与病理测量及T分期的对应关系。长轴径与病理测量相关性更强(ICC 0.808 vs 0.730),CT T分期与病理T分期在超过20%的结节中不一致(P <.001)。作者认为长轴径更适于T分期,平均径因测量变异性更小且评估更保守,可用于纵向随访。

要点

  • CT长轴径与病理测量相关性优于平均径(ICC 0.808 vs 0.730)。
  • CT T分期与病理T分期在超过20%的结节中不一致(P <.001)。
  • 肺窗测量与病理相关性优于纵隔窗测量。

核心结论

  • CT长轴径更适于T分期,因其更好地反映病理T分期;平均径因测量变异性更小且评估更保守,可用于结节纵向随访。

研究设计与样本

  • 经机构审查委员会批准的影像-病理对照研究,纳入本机构10年间切除的274例影像学实性腺癌;两名观察者在术前胸部CT肺窗和纵隔窗上测量长轴径和短轴径并确定T分期,以病理测量和病理T分期为参考标准,采用Wilcoxon符号秩检验和McNemar检验进行比较,采用组内相关系数(ICC)和Bland-Altman图评估观察者间和观察者内变异性。

诊断标准与关键数值

  • 肺窗长轴径16.93 mm vs 平均径14.92 mm,长轴径显著更大(P <.001)。
  • 纵隔窗长轴径14.02 mm vs 平均径12.17 mm,长轴径显著更大(P <.001)。
  • 肺窗CT与病理测量ICC:长轴径0.808 vs 平均径0.730。
  • 纵隔窗CT与病理测量ICC:长轴径0.731 vs 平均径0.621。
  • CT T分期与病理T分期在超过20%的结节中不一致(P <.001)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study aimed to compare long-axis diameter to average computed tomography (CT) diameter measurements of lung adenocarcinomas manifesting as solid lung nodules ≤30 mm on CT, as referenced to pathologic measurements, and to determine the impact of the two CT measurement approaches on tumor (T)-staging of nodules.

MATERIALS AND METHODS: This institutional review board-approved study included all 274 radiologic solid adenocarcinomas resected at our institution over 10 years. Two observers measured long- and short-axis diameters on pre-resection chest CT in lung and mediastinal windows. T-stages were determined. CT measurements and T-stages were compared to pathology measurements and T-stages using Wilcoxon signed rank test and McNemar test. Inter- and intraobserver variability was determined with intraclass correlation coefficients (ICC) and Bland-Altman plots.

RESULTS: For lung and mediastinal windows, nodule size was significantly larger using long-axis diameter rather than average diameter (16.93 vs. 14.92 mm, P <.001; and 14.02 vs. 12.17 mm, P <.001, respectively). The correlation of CT with pathologic measurements was stronger with long-axis than with average diameter (ICC 0.808 vs. 0.730; and 0.731 vs. 0.621, respectively). Lung window measurements correlated stronger with pathology than mediastinal window measurements. CT T-stages differed from pathology T-stages in more than 20% of nodules (P <.001). Inter- and intraobserver variability was small with long-axis and average diameter (ICC range 0.96-0.991, and 0.970-0.993, respectively), but long-axis diameter showed wider scatter on Bland-Altman plots.

CONCLUSIONS: Long-axis CT diameter is preferable for T-staging because it better reflects the pathology T-stage. Average CT diameter might be used for longitudinal nodule follow-up because it shows less measurement variability and is more conservative in size assessment.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Heidinger BH, Anderson KR, Moriarty EM, et al. Size Measurement and T-staging of Lung Adenocarcinomas Manifesting as Solid Nodules ≤30 mm on CT: Radiology-Pathology Correlation. Acad Radiol. 2017. PMID: 28256438. doi:10.1016/j.acra.2017.01.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。