标准剂量、缩减剂量与无辐射薄层影像检查:疑似肺结节患者结节检出与结节类型评估能力的比较
本研究纳入52例疑似肺结节患者,比较标准剂量CT(250 mA)、缩减剂量CT(60 mA)与超短回波时间(UTE)薄层MR在结节检出及类型评估中的能力。三种方法的品质因子无显著差异(标准剂量CT 0.86、缩减剂量CT 0.84、UTE MR 0.86),敏感度无显著差异,结节类型分类的组间一致性极好(κ=0.98–0.99)。作者认为UTE薄层MR在结节检出和类型评估上有用,至少与标准或缩减剂量薄层CT等效。
要点
- 标准剂量CT、缩减剂量CT与UTE MR的品质因子分别为0.86、0.84、0.86,无显著差异(F=0.70,P=.59)。
- 三种方法两两比较结节检出敏感度均无显著差异(P=.50、P=.50、P>.99)。
- 结节类型分类组间一致性极好(κ=0.98–0.99,P<.001)。
核心结论
- 疑似肺结节患者中,UTE薄层MR在结节检出和结节类型评估上有用,且被认为至少与标准剂量或缩减剂量薄层CT等效。
研究设计与样本
- 经机构审查委员会批准并获书面知情同意的前瞻性对照研究,纳入52例疑似肺结节患者(男29例,平均年龄66.4岁±7.3,范围48–79岁;女23例,平均年龄64.8岁±10.1,范围42–83岁),行标准剂量(250 mA)与缩减剂量(60 mA)胸部CT及UTE MR检查。
诊断标准与关键数值
- 采用五点视觉评分系统评估结节存在概率;结节分为漏诊、磨玻璃、部分实性和实性结节;以jackknife自由响应受试者工作特征分析比较检出能力,以κ分析比较结节类型分类的组间一致性。
临床应用与阅片要点
- 阅片时可参照五点视觉评分系统评估结节存在概率,并按漏诊、磨玻璃、部分实性、实性四类进行结节分类。
- 标准剂量CT、缩减剂量CT与UTE MR在结节检出敏感度上无显著差异,结节类型分类组间一致性极好(κ=0.98–0.99)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare the capability of pulmonary thin-section magnetic resonance (MR) imaging with ultrashort echo time (UTE) with that of standard- and reduced-dose thin-section computed tomography (CT) in nodule detection and evaluation of nodule type. Materials and Methods The institutional review board approved this study, and written informed consent was obtained from each patient. Standard- and reduced-dose chest CT (60 and 250 mA) and MR imaging with UTE were used to examine 52 patients; 29 were men (mean age, 66.4 years ± 7.3 [standard deviation]; age range, 48-79 years) and 23 were women (mean age, 64.8 years ± 10.1; age range, 42-83 years). Probability of nodule presence was assessed for all methods with a five-point visual scoring system. All nodules were then classified as missed, ground-glass, part-solid, or solid nodules. To compare nodule detection capability of the three methods, consensus for performances was rated by using jackknife free-response receiver operating characteristic analysis, and κ analysis was used to compare intermethod agreement for nodule type classification. Results There was no significant difference (F = 0.70, P = .59) in figure of merit between methods (standard-dose CT, 0.86; reduced-dose CT, 0.84; MR imaging with UTE, 0.86). There was no significant difference in sensitivity between methods (standard-dose CT vs reduced-dose CT, P = .50; standard-dose CT vs MR imaging with UTE, P = .50; reduced-dose CT vs MR imaging with UTE, P >.99). Intermethod agreement was excellent (standard-dose CT vs reduced-dose CT, κ = 0.98, P < .001; standard-dose CT vs MR imaging with UTE, κ = 0.98, P < .001; reduced-dose CT vs MR imaging with UTE, κ = 0.99, P < .001). Conclusion Pulmonary thin-section MR imaging with UTE was useful in nodule detection and evaluation of nodule type, and it is considered at least as efficacious as standard- or reduced-dose thin-section CT. © RSNA, 2017 Online supplemental material is available for this article.
引用
- Ohno Y, Koyama H, Yoshikawa T, et al. Standard-, Reduced-, and No-Dose Thin-Section Radiologic Examinations: Comparison of Capability for Nodule Detection and Nodule Type Assessment in Patients Suspected of Having Pulmonary Nodules. Radiology. 2017. PMID: 28263700. doi:10.1148/radiol.2017161037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。