100 kVp 锡滤过光谱滤过单能量儿童胸部 CT:对辐射参数与图像质量的影响
研究纳入了33例非增强胸部CT儿童,在第三代双源CT上采用100 kVp锡滤过光谱滤过扫描,并与标准100 kVp单源胸部CT比较。结果显示光谱滤过组有效管电流最高增加至10倍,但图像信噪比、噪声及主观质量无显著差异;5岁及以下儿童辐射剂量相当,较大儿童辐射剂量中度降低(P=0.006)。
要点
- 100 kVp锡滤过光谱滤过儿童胸部CT可提供与标准单源CT相似的客观及主观图像质量。
- 光谱滤过技术使有效管电流显著增加(P=0.0001),最高可达10倍。
- 5岁及以下儿童辐射剂量与标准CT相当,较大儿童辐射剂量中度降低(P=0.006)。
核心结论
- 在第三代双源CT上使用100 kVp管基锡滤过光谱滤过行儿童胸部CT,有效管电流最高增加至10倍,可在与标准单源CT未滤过扫描相当的剂量下提供相似的图像质量。
研究设计与样本
- 研究纳入33例转诊行非增强胸部CT的儿童,在第三代双源CT上采用100 kVp锡滤过光谱滤过扫描(管电流时间积使剂量与标准方案相当),并与采用标准100 kVp单源胸部CT检查的儿童图像进行比较;评估客观与主观图像质量并比较辐射剂量参数。
诊断标准与关键数值
- 光谱滤过组与标准单源CT组信噪比和图像噪声相似(P≥0.06)。
- 光谱滤过组与标准单源CT组主观图像质量无显著差异(P≥0.2)。
- 5岁及以下儿童两组辐射剂量相当;较大儿童使用光谱滤过时辐射剂量中度降低(P=0.006)。
- 使用光谱滤过时有效管电流显著增加(P=0.0001),最高达10倍。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Most of the applied radiation dose at CT is in the lower photon energy range, which is of limited diagnostic importance.
OBJECTIVE: To investigate image quality and effects on radiation parameters of 100-kVp spectral filtration single-energy chest CT using a tin-filter at third-generation dual-source CT in comparison to standard 100-kVp chest CT.
MATERIALS AND METHODS: Thirty-three children referred for a non-contrast chest CT performed on a third-generation dual-source CT scanner were examined at 100 kVp with a dedicated tin filter with a tube current-time product resulting in standard protocol dose. We compared resulting images with images from children examined using standard single-source chest CT at 100 kVp. We assessed objective and subjective image quality and compared radiation dose parameters.
RESULTS: Radiation dose was comparable for children 5 years old and younger, and it was moderately decreased for older children when using spectral filtration (P=0.006). Effective tube current increased significantly (P=0.0001) with spectral filtration, up to a factor of 10. Signal-to-noise ratio and image noise were similar for both examination techniques (P≥0.06). Subjective image quality showed no significant differences (P≥0.2).
CONCLUSION: Using 100-kVp spectral filtration chest CT in children by means of a tube-based tin-filter on a third-generation dual-source CT scanner increases effective tube current up to a factor of 10 to provide similar image quality at equivalent dose compared to standard single-source CT without spectral filtration.
引用
- Bodelle B, Fischbach C, Booz C, et al. Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality. Pediatr Radiol. 2017. PMID: 28352977. doi:10.1007/s00247-017-3813-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。