利用超声多次散射表征肺实质
研究基于8 MHz线阵探头,通过分离近场相干与非相干强度并测量非相干扩散晕随时间增长,估计大鼠在体肺实质的扩散常数D和传输平均自由程L*;健康鼠L*为332 μm(±48.8 μm),水肿鼠为1040 μm(±90 μm),差异显著;仿真与海绵体模中空气体积分数与L*显著相关(r=-0.9542,p<0.0117;r=-0.9932,p<0.0068),离体注液实验显示液体体积分数与L*呈线性关系。
要点
- 8 MHz线阵探头接触肺表面,可估计肺实质传输平均自由程L*与扩散常数D。
- 在体大鼠肺L*:健康332 μm(±48.8 μm),水肿1040 μm(±90 μm),差异显著。
- 仿真与海绵体模中空气体积分数与L*显著负相关,离体液体体积分数与L*呈线性关系。
核心结论
- 基于超声多次散射的方法具有定量表征肺实质的潜力。
研究设计与样本
- 实验研究,采用8 MHz中心频率线阵探头接触肺表面,在体大鼠肺、海绵体模、兔肺组织学图像二维有限差分时域数值仿真及离体大鼠肺中估计扩散常数D和传输平均自由程L*。
关键影像表现/征象
- 通过分离近场非相干与相干强度并测量非相干扩散晕随时间增长来估计L*和D。
- 在体大鼠肺L*:健康对照组332 μm(±48.8 μm)vs 水肿组1040 μm(±90 μm),差异显著。
- 仿真中空气体积分数与L*显著相关(r=-0.9542,p<0.0117)。
- 海绵体模中空气体积分数与L*显著相关(r=-0.9932,p<0.0068)。
- 离体大鼠肺注液模拟水肿后,液体体积分数与L*呈线性关系。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The purpose of the study described here was to showcase the application of ultrasound to quantitative characterization of the micro-architecture of the lung parenchyma to predict the extent of pulmonary edema. The lung parenchyma is a highly complex and diffusive medium for which ultrasound techniques have remained qualitative. The approach presented here is based on ultrasound multiple scattering and exploits the complexity of ultrasound propagation in the lung structure. The experimental setup consisted of a linear transducer array with an 8-MHz central frequency placed in contact with the lung surface. The diffusion constant D and transport mean free path L* of the lung parenchyma were estimated by separating the incoherent and coherent intensities in the near field and measuring the growth of the incoherent diffusive halo over time. Significant differences were observed between the L* values obtained in healthy and edematous rat lungs in vivo. In the control rat lung, L* was found to be 332 μm (±48.8 μm), whereas in the edematous lung, it was 1040 μm (±90 μm). The reproducibility of the measurements of L* and D was tested in vivo and in phantoms made of melamine sponge with varying air volume fractions. Two-dimensional finite difference time domain numerical simulations were carried out on rabbit lung histology images with varying degrees of lung collapse. Significant correlations were observed between air volume fraction and L* in simulation (r = -0.9542, p < 0.0117) and sponge phantom (r = -0.9932, p < 0.0068) experiments. Ex vivo measurements of a rat lung in which edema was simulated by adding phosphate-buffered saline revealed a linear relationship between the fluid volume fraction and L*. These results illustrate the potential of methods based on ultrasound multiple scattering for the quantitative characterization of the lung parenchyma.
引用
- Mohanty K, Blackwell J, Egan T, et al. Characterization of the Lung Parenchyma Using Ultrasound Multiple Scattering. Ultrasound Med Biol. 2017. PMID: 28318888. doi:10.1016/j.ultrasmedbio.2017.01.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。