文献速递腹部胸部CTDR

腐蚀性食管癌:食管造影与CT表现

Corrosive-Induced Carcinoma of Esophagus: Esophagographic and CT Findings.
PubMed 文献 · AJR Am J Roentgenol · 2017-03-23

该回顾性研究纳入1989年6月至2015年4月单中心15例经组织病理学证实的腐蚀性食管癌患者,分析其食管造影(13例)与胸部CT(14例)表现;结论为食管造影常见狭窄段息肉样肿块伴长段黏膜不规则、不对称受累及僵硬,CT示偏心性管壁增厚伴均匀强化及食管周围浸润,提示腐蚀性食管狭窄患者可能发生恶变。

要点

  • 腐蚀性食管癌在食管造影上常表现为狭窄段息肉样肿块,伴长段黏膜不规则、不对称受累及管壁僵硬。
  • CT上常见偏心性食管壁增厚、均匀强化及食管周围浸润,提示腐蚀性食管狭窄患者可能发生恶变。
  • 本病影像学表现以狭窄段受累为主(13例中10例,76.9%),阅片时应重点观察狭窄段的形态与黏膜改变。

核心结论

  • 食管造影常见腐蚀性食管癌为狭窄段息肉样肿块伴长段黏膜不规则、不对称受累及僵硬;CT示偏心性管壁增厚伴均匀强化及食管周围浸润,提示腐蚀性食管狭窄患者可能发生恶变。

研究设计与样本

  • 单中心回顾性研究,1989年6月至2015年4月共纳入15例经组织病理学证实的腐蚀性食管癌患者,其中13例行食管造影、14例行胸部CT,由两名阅片者独立判读。

关键影像表现/征象

  • 食管造影显示肿瘤累及狭窄段者13例中10例(76.9%)。
  • 食管造影最常见的形态学表现为息肉样肿块,共10例;12例(92.3%)可见黏膜不规则,受累平均长度4.92 cm。
  • 食管造影显示不对称受累和僵硬各9例(69.2%)。
  • CT显示偏心性管壁增厚14例中10例(71.4%),均匀强化9例(64.2%),食管周围浸润11例(78.5%)。

临床应用与阅片要点

  • 对腐蚀性食管狭窄患者,食管造影应关注狭窄段是否出现息肉样肿块、长段黏膜不规则、不对称受累及僵硬。
  • 胸部CT阅片时应评估偏心性管壁增厚、均匀强化及食管周围浸润,这些表现提示腐蚀性食管狭窄患者可能发生恶变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to evaluate the esophagographic and CT findings of corrosive esophageal cancer.

MATERIALS AND METHODS: The records of all patients who presented with corrosive esophageal strictures at one institution between June 1989 and April 2015 were retrospectively identified. The search yielded the records of 15 patients with histopathologically proven esophageal cancer. Esophagograms (13 patients) and chest CT images (14 patients) were interpreted independently by two reviewers. Esophagographic findings included the location of tumor, morphologic type, presence and length of mucosal irregularity, presence of asymmetric involvement, and presence of rigidity. CT findings included presence and type of esophageal wall thickening, pattern of enhancement, presence of periesophageal infiltration, and presence of hilar or mediastinal lymphadenopathy.

RESULTS: Esophagography showed that the tumor was involved with the stenotic portion in 10 of the 13 patients (76.9%). The most common morphologic feature was a polypoid mass, in 10 patients. In 12 patients (92.3%), mucosal irregularities were observed; the mean affected length was 4.92 cm. Asymmetric involvement and rigidity were observed in nine patients (69.2%). On CT scans, eccentric wall thickening was observed in 10 of the 14 patients (71.4%), homogeneous enhancement in nine (64.2%), and periesophageal infiltration in 11 (78.5%).

CONCLUSION: Esophagography commonly shows corrosive esophageal cancer as a polypoid mass with long-segment mucosal irregularities at the stenotic portion, asymmetric involvement, and rigidity. CT shows eccentric esophageal wall thickening with homogeneous enhancement and periesophageal infiltration, which are suggestive of the development of malignancy in patients with corrosive esophageal strictures.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Noh SY, Kim HJ, Lee HJ, et al. Corrosive-Induced Carcinoma of Esophagus: Esophagographic and CT Findings. AJR Am J Roentgenol. 2017. PMID: 28333543. doi:10.2214/AJR.16.17138

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。