扩散张量成像与扩散加权成像鉴别头颈部良恶性病变
回顾性研究纳入65例头颈部病变患者(71个良性、40个恶性),比较DTI与DWI的ADC值及病灶与延髓ADC比值。恶性病变DTI ADC值显著低于良性(0.55×10⁻³ vs 0.89×10⁻³ mm²/s,p<0.001),ADC比值阈值DTI≤1、DWI≤0.94相近,DTI可用于预测恶性。
要点
- DTI参数下恶性病变ADC值显著低于良性(p<0.001),ADC比值恶性0.88 vs 良性1.40。
- DTI与DWI的ADC比值相近,预测恶性阈值DTI≤1、DWI≤0.94。
- 本研究组所有头颈部病变DTI ADC值均低于DWI ADC值,常低于已报道的恶性DWI阈值。
核心结论
- DTI是预测头颈部病变恶性的有用指标,恶性病变ADC值显著低于良性;以内部对照归一化后DTI与DWI的ADC比值相近。
研究设计与样本
- 回顾性研究,纳入65例头颈部病变患者(71个良性、40个恶性,21例有多发病灶),临床MRI采用1.5或3 T并含DWI或DTI参数,ROI分析生成病灶与延髓ADC比值。
诊断标准与关键数值
- DTI参数下恶性病变平均ADC值0.55×10⁻³±0.14×10⁻³ mm²/s vs 良性0.89×10⁻³±0.29×10⁻³ mm²/s(p<0.001);恶性ADC比值0.88±0.21 vs 良性1.40±0.44。预测恶性阈值:DTI ADC比值≤1,DWI ADC比值≤0.94。
临床应用与阅片要点
- DTI与DWI的ADC比值相近,DTI ADC比值≤1可作为预测头颈部病变恶性的参考阈值。
局限性
- 本研究为回顾性研究。
- 本研究组所有头颈部病变DTI ADC值均低于DWI ADC值,常低于已报道的恶性DWI阈值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study was to determine whether diffusion tensor imaging (DTI) can be used to differentiate between benign and malignant head and neck lesions.
MATERIALS AND METHODS: This retrospective study included patients with head and neck lesions who underwent clinical MRI at 1.5 or 3 T with DWI or DTI parameters. ROI analysis was performed, with lesion-to-medulla apparent diffusion coefficient (ADC) ratios generated.
RESULTS: Sixty-five patients with head and neck lesions were included (71 benign, 40 malignant). Twenty-one patients had multiple lesions. Statistically significant differences (p < 0.001) were seen in the mean ADC values ± SD of malignant and benign lesions (0.55 × 10-3 ± 0.14 × 10-3 mm2/s vs 0.89 × 10-3 ± 0.29 × 10-3 mm2/s, respectively) and in the mean ADC ratios of malignant and benign lesions (0.88 ± 0.21 vs 1.40 ± 0.44, respectively) with DTI parameters. DTI and DWI parameters produced similar mean ADC ratio values for malignant (0.88 ± 0.21 and 0.92 ± 0.54, respectively) and benign lesions (1.40 ± 0.44 and 1.79 ± 0.52, respectively). ADC ratio thresholds for predicting malignancy for DTI (ADC ratio ≤ 1) and DWI (ADC ratio ≤ 0.94) were also similar.
CONCLUSION: DTI is a useful predictor of malignancy for head and neck lesions, with ADC values of malignant lesions significantly lower than those of benign lesions. DTI ADC values were lower than DWI ADC values for all head and neck lesions in our study group, often below reported malignant DWI threshold values. Normalization of ADC values to an internal control resulted in similar ADC ratios on DWI and DTI.
引用
- Koontz NA, Wiggins RH. Differentiation of Benign and Malignant Head and Neck Lesions With Diffusion Tensor Imaging and DWI. AJR Am J Roentgenol. 2017. PMID: 28245145. doi:10.2214/AJR.16.16486
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。