文献速递神经外周血管MR

动脉壁强化评估用于区分父动脉疾病与小动脉疾病:3T三维对比增强T1加权涡轮自旋回波MR图像直方图分析与视觉分析的比较

Assessment of Arterial Wall Enhancement for Differentiation of Parent Artery Disease from Small Artery Disease: Comparison between Histogram Analysis and Visual Analysis on 3-Dimensional Contrast-Enhanced T1-Weighted Turbo Spin Echo MR Images at 3T.
PubMed 文献 · Korean J Radiol · 2017-02-07

本研究在3T MRI上比较直方图分析与视觉评分评估大脑中动脉壁强化以区分父动脉疾病(PAD)与小动脉疾病(SAD)的价值。纳入25例急性梗死患者(PAD 15例,SAD 10例),结果显示PAD组狭窄程度、视觉强化评分、直方图几何均值(GM)和第90百分位值(90P)均显著高于SAD组,GM和90P的ROC曲线下面积为1(95%CI 0.86-1.00)。直方图分析可区分PAD与SAD。

要点

  • 直方图GM和90P鉴别PAD与SAD的AUC为1(95%CI 0.86-1.00)。
  • PAD组狭窄程度、视觉强化评分、GM和90P均显著高于SAD组。
  • 直方图分析动脉壁强化有助于区分急性卒中患者的PAD与SAD。

核心结论

  • 相关动脉壁强化的直方图分析可区分大脑中动脉供血区急性卒中患者的PAD与SAD。

研究设计与样本

  • 回顾性纳入一家三级医院一年内82例连续患者中的25例大脑中动脉供血区急性梗死患者(PAD 15例,SAD 10例),采用3T三维对比增强T1加权涡轮自旋回波MR成像(黑血准备),进行定性和定量分析。

关键影像表现/征象

  • PAD组大脑中动脉狭窄程度显著高于SAD组(p=0.006)。
  • PAD组视觉强化评分显著高于SAD组(p<0.001)。
  • PAD组直方图几何均值(GM)显著高于SAD组(p<0.001)。
  • PAD组直方图第90百分位值(90P)显著高于SAD组(p<0.001)。

诊断标准与关键数值

  • 直方图GM鉴别PAD与SAD的ROC曲线下面积为1(95%CI 0.86-1.00)。
  • 直方图90P鉴别PAD与SAD的ROC曲线下面积为1(95%CI 0.86-1.00)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to compare the histogram analysis and visual scores in 3T MRI assessment of middle cerebral arterial wall enhancement in patients with acute stroke, for the differentiation of parent artery disease (PAD) from small artery disease (SAD).

MATERIALS AND METHODS: Among the 82 consecutive patients in a tertiary hospital for one year, 25 patients with acute infarcts in middle cerebral artery (MCA) territory were included in this study including 15 patients with PAD and 10 patients with SAD. Three-dimensional contrast-enhanced T1-weighted turbo spin echo MR images with black-blood preparation at 3T were analyzed both qualitatively and quantitatively. The degree of MCA stenosis, and visual and histogram assessments on MCA wall enhancement were evaluated. A statistical analysis was performed to compare diagnostic accuracy between qualitative and quantitative metrics.

RESULTS: The degree of stenosis, visual enhancement score, geometric mean (GM), and the 90th percentile (90P) value from the histogram analysis were significantly higher in PAD than in SAD (p = 0.006 for stenosis, < 0.001 for others). The receiver operating characteristic curve area of GM and 90P were 1 (95% confidence interval [CI], 0.86-1.00).

CONCLUSION: A histogram analysis of a relevant arterial wall enhancement allows differentiation between PAD and SAD in patients with acute stroke within the MCA territory.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Jang J, Kim TW, Hwang EJ, et al. Assessment of Arterial Wall Enhancement for Differentiation of Parent Artery Disease from Small Artery Disease: Comparison between Histogram Analysis and Visual Analysis on 3-Dimensional Contrast-Enhanced T1-Weighted Turbo Spin Echo MR Images at 3T. Korean J Radiol. 2017. PMID: 28246519. doi:10.3348/kjr.2017.18.2.383

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。