利用影像定位活检构建胶质母细胞瘤细胞密度多参数预测模型
研究对36例胶质母细胞瘤患者的91份影像定位活检标本进行分析,采用自动配准算法获取T1增强减影、T2-FLAIR和ADC序列的信号强度,并用自动细胞计数算法计算细胞密度。结果显示T2-FLAIR(r=-0.61)和ADC(r=-0.63)与细胞密度呈负相关,T1增强减影(r=0.69)呈正相关,联合多参数模型相关性提高(r=0.74),提示各序列提供互补信息,该模型可用于映射肿瘤内异质性。
要点
- T2-FLAIR信号与细胞密度呈负相关(r=-0.61),ADC与细胞密度呈负相关(r=-0.63)。
- T1增强减影信号与细胞密度呈正相关(r=0.69)。
- 联合T1增强减影、T2-FLAIR和ADC的多参数模型相关性提高(r=0.74)。
核心结论
- 基于影像定位活检构建的模型显示MR信号与细胞密度之间存在定量且显著的关系,将该关系投射至整个肿瘤体积可映射胶质母细胞瘤增强核心和非增强边缘的瘤内异质性,可能用于指导扩大手术切除、定位活检和放疗野勾画。
研究设计与样本
- 研究纳入36例胶质母细胞瘤患者,获取91份影像定位活检标本;信号强度由T1增强减影、T2-FLAIR和ADC序列经自动配准算法获得,细胞密度由自动细胞计数算法计算。
关键影像表现/征象
- T2-FLAIR信号强度与细胞密度呈负相关(r=-0.61)。
- ADC信号强度与细胞密度呈负相关(r=-0.63)。
- T1增强减影信号强度与细胞密度呈正相关(r=0.69)。
- 联合上述序列的多参数模型与细胞密度的相关性提高(r=0.74),提示各序列提供不同且互补的信息。
诊断标准与关键数值
- T2-FLAIR与细胞密度的相关系数r=-0.61。
- ADC与细胞密度的相关系数r=-0.63。
- T1增强减影与细胞密度的相关系数r=0.69。
- 多参数模型与细胞密度的相关系数r=0.74。
临床应用与阅片要点
- 作者指出,将信号-细胞密度关系投射至整个肿瘤体积可映射增强核心与非增强边缘的瘤内异质性。
- 作者指出,该模型可能用于指导扩大手术切除、定位活检和放疗野勾画。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The complex MR imaging appearance of glioblastoma is a function of underlying histopathologic heterogeneity. A better understanding of these correlations, particularly the influence of infiltrating glioma cells and vasogenic edema on T2 and diffusivity signal in nonenhancing areas, has important implications in the management of these patients. With localized biopsies, the objective of this study was to generate a model capable of predicting cellularity at each voxel within an entire tumor volume as a function of signal intensity, thus providing a means of quantifying tumor infiltration into surrounding brain tissue.
MATERIALS AND METHODS: Ninety-one localized biopsies were obtained from 36 patients with glioblastoma. Signal intensities corresponding to these samples were derived from T1-postcontrast subtraction, T2-FLAIR, and ADC sequences by using an automated coregistration algorithm. Cell density was calculated for each specimen by using an automated cell-counting algorithm. Signal intensity was plotted against cell density for each MR image.
RESULTS: T2-FLAIR (r = -0.61) and ADC (r = -0.63) sequences were inversely correlated with cell density. T1-postcontrast (r = 0.69) subtraction was directly correlated with cell density. Combining these relationships yielded a multiparametric model with improved correlation (r = 0.74), suggesting that each sequence offers different and complementary information.
CONCLUSIONS: Using localized biopsies, we have generated a model that illustrates a quantitative and significant relationship between MR signal and cell density. Projecting this relationship over the entire tumor volume allows mapping of the intratumoral heterogeneity in both the contrast-enhancing tumor core and nonenhancing margins of glioblastoma and may be used to guide extended surgical resection, localized biopsies, and radiation field mapping.
引用
- Chang PD, Malone HR, Bowden SG, et al. A Multiparametric Model for Mapping Cellularity in Glioblastoma Using Radiographically Localized Biopsies. AJNR Am J Neuroradiol. 2017. PMID: 28255030. doi:10.3174/ajnr.A5112