文献速递神经妇产影像MRUS

MERIDIAN队列的解剖亚组分析:脑室扩大

Anatomical subgroup analysis of the MERIDIAN cohort: ventriculomegaly.
PubMed 文献 · Ultrasound Obstet Gynecol · 2017-11-05

该研究为MERIDIAN研究的亚组分析,纳入306例产前超声仅发现脑室扩大(VM)的胎儿,评估胎儿MRI的诊断价值。超声总体诊断准确率89.9%,MRI为98.7%(P<0.0001);MRI改变了23.4%病例的预后分类,25.8%病例的临床处理影响为「显著」「重大」或「决定性」。作者认为对超声仅见VM的胎儿应提供MRI辅助检查。

要点

  • 超声仅见脑室扩大的胎儿中,MRI可检出超声漏诊的额外脑部异常,总体诊断准确率98.7%对89.9%。
  • 轻度脑室扩大胎儿中,MRI诊断准确率99.2%对超声94.3%(P=0.0005)。
  • MRI未系统性高估或低估侧脑室三角区尺寸,仅16%病例存在分类差异。

核心结论

  • 数据提示,对超声仅发现脑室扩大作为唯一颅内异常的胎儿,应提供MRI辅助检查以进一步评估。

研究设计与样本

  • MERIDIAN研究的亚组分析,纳入306例超声仅诊断脑室扩大、且在2周内接受MRI检查并有结局参考数据的胎儿;比较超声与MRI相对于严重程度的诊断准确率、两种方法测量的三角区尺寸差异及MRI的临床影响。

关键影像表现/征象

  • 超声仅见脑室扩大的胎儿中,超声漏诊31处额外脑部异常,MRI正确检出其中27处。
  • 轻度脑室扩大(超声)的244例胎儿中,14例存在其他脑部异常,MRI正确诊断其中12例。
  • 超声与MRI测量的侧脑室三角区尺寸高度一致,仅16%病例存在分类差异,MRI未系统性高估或低估三角区尺寸。

诊断标准与关键数值

  • 超声总体诊断准确率89.9%,MRI总体诊断准确率98.7%(P<0.0001)。
  • 轻度脑室扩大胎儿中,超声诊断准确率94.3%,MRI诊断准确率99.2%(P=0.0005)。
  • MRI后295例中有69例(23.4%)预后分类发生改变。
  • MRI对临床处理的影响在295例中有76例(25.8%)被评为「显著」「重大」或「决定性」。

临床应用与阅片要点

  • 作者认为,对超声仅见脑室扩大作为唯一颅内异常的胎儿,应提供MRI辅助检查以进一步评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the contribution of fetal magnetic resonance imaging (MRI) in fetuses of the MERIDIAN cohort diagnosed with ventriculomegaly (VM) as the only abnormal intracranial finding on antenatal ultrasound.

METHODS: This was a subgroup analysis of the MERIDIAN study of fetuses with only VM diagnosed on ultrasound in women who had a subsequent MRI examination within 2 weeks and for whom outcome reference data were available. The diagnostic accuracy of ultrasound and MRI was reported in relation to the severity of VM. The difference in measurements of trigone size on the two imaging methods and the clinical impact of adding MRI to the diagnostic pathway were also studied.

RESULTS: In 306 fetuses with VM, ultrasound failed to detect 31 additional brain abnormalities, having an overall diagnostic accuracy of 89.9% for ultrasound, whilst MRI correctly detected 27 of the additional brain abnormalities, having a diagnostic accuracy of 98.7% (P < 0.0001). There were other brain abnormalities in 14/244 fetuses with mild VM on ultrasound (diagnostic accuracy, 94.3%) and MRI correctly diagnosed 12 of these (diagnostic accuracy, 99.2%; P = 0.0005). There was a close agreement between the size of trigones measured on ultrasound and on MRI, with categorical differences in only 16% of cases, showing that MRI did not systematically overestimate or underestimate trigone size. Complete prognostic data were available in 295/306 fetuses and the prognosis category changed after MRI in 69/295 (23.4%) cases. The overall effect of MRI on clinical management was considered to be 'significant', 'major' or 'decisive' in 76/295 (25.8%) cases.

CONCLUSION: Our data suggest that a woman carrying a fetus with VM as the only intracranial finding on ultrasound should be offered an adjuvant investigation by MRI for further evaluation. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Griffiths PD, Brackley K, Bradburn M, et al. Anatomical subgroup analysis of the MERIDIAN cohort: ventriculomegaly. Ultrasound Obstet Gynecol. 2017. PMID: 28337830. doi:10.1002/uog.17475

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。