文献速递神经外周血管MR

MR血管成像量化颅内颈内动脉狭窄

Quantifying Intracranial Internal Carotid Artery Stenosis on MR Angiography.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-03-16

研究基于前瞻性卒中登记,在386条颅内颈内动脉的MRA上比较最窄处单一直径测量与Warfarin-Aspirin Symptomatic Intracranial Disease(WASID)法狭窄百分比的相关性,发现两者呈强线性相关(R=-0.84),直径≤2.1 mm和≤1.3 mm分别最佳识别≥50%和≥70%狭窄。

要点

  • MRA上颅内ICA最窄处单一直径与WASID法狭窄百分比强线性相关(R=-0.84)。
  • 直径≤2.1 mm为识别≥50%狭窄的最佳阈值(AUC=0.96)。
  • 直径≤1.3 mm为识别≥70%狭窄的最佳阈值(AUC=0.99)。

核心结论

  • 颅内ICA最窄处管腔直径与WASID法狭窄百分比呈强线性相关,单一直径测量可能准确估算WASID狭窄,可能影响风险分层和治疗决策。

研究设计与样本

  • 从前瞻性卒中登记中识别接受头部MRA的患者,定量评估每条颅内ICA的WASID法狭窄程度,并在最大狭窄处行单一线性毫米测量,共386条颅内ICA。

关键影像表现/征象

  • 在386条颅内ICA中,单一管腔测量与WASID法狭窄测量呈强线性关系(R=-0.84,P<.0001)。

诊断标准与关键数值

  • ICA管腔直径≤2.1 mm为识别≥50%狭窄的最佳阈值(AUC=0.96)。
  • ICA管腔直径≤1.3 mm为识别≥70%狭窄的最佳阈值(AUC=0.99)。

临床应用与阅片要点

  • 作者认为MRA上单一直径测量可准确估算WASID法狭窄,可能影响风险分层和治疗决策。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Intracranial atherosclerosis is a common cause of ischemic stroke. Intracranial stenosis is most commonly quantified by the Warfarin-Aspirin Symptomatic Intracranial Disease method, which involves calculating a ratio of luminal diameter measurements on conventional angiography. Our purpose was to determine whether a single linear measurement of the narrowest caliber of the intracranial ICA on MRA can accurately predict Warfarin-Aspirin Symptomatic Intracranial Disease stenosis measurements.

MATERIALS AND METHODS: We identified patients from a prospective stroke registry who had undergone head MRAs to quantitatively evaluate the degree of Warfarin-Aspirin Symptomatic Intracranial Disease-derived stenosis in each intracranial ICA. We also made a single linear millimeter measurement at the site of maximal narrowing of the ICA. We calculated a correlation coefficient between the lumen diameter in millimeters and percentage Warfarin-Aspirin Symptomatic Intracranial Disease stenosis. We performed receiver operating characteristic analysis to determine optimal luminal diameter cutoff values.

RESULTS: In 386 unique intracranial ICAs, we found a strong linear relationship between single lumen measurements and Warfarin-Aspirin Symptomatic Intracranial Disease-style stenosis measurements (R = -0.84, P < .0001). We found that ICA lumen diameters of ≤2.1 and ≤1.3 mm were optimal cutoffs for identifying patients with ≥50% stenosis and ≥70% stenosis, respectively (area under the curve = 0.96 and 0.99, respectively).

CONCLUSIONS: There is a strong linear relationship between the narrowest lumen diameter of the intracranial ICA and percentage stenosis. Our results suggest that a single lumen diameter measurement on MRA allows accurate estimation of Warfarin-Aspirin Symptomatic Intracranial Disease stenosis, which may affect risk stratification and treatment decisions.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Baradaran H, Patel P, Gialdini G, et al. Quantifying Intracranial Internal Carotid Artery Stenosis on MR Angiography. AJNR Am J Neuroradiol. 2017. PMID: 28302605. doi:10.3174/ajnr.A5113

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。