剪切波超声弹性成像评估卒中后痉挛肌肉硬度
研究采用声辐射力脉冲剪切波速度(SWV)检测肱二头肌硬度,在21名对照者中优势侧与非优势侧SWV无显著差异,在31例近期卒中患者中瘫痪侧在90°和0°屈肘时SWV均显著高于非瘫痪侧。90°时瘫痪侧SWV与改良Ashworth量表及改良Tardieu量表正相关、与卒中康复运动评估评分负相关,组内与组间信度均为优。
要点
- 卒中后瘫痪侧肱二头肌SWV在90°屈肘为2.23±0.15 m/s,高于非瘫痪侧的1.88±0.08 m/s。
- 0°屈肘时瘫痪侧SWV为3.28±0.11 m/s,高于非瘫痪侧的2.93±0.06 m/s。
- 90°时瘫痪侧SWV与痉挛严重程度正相关、与运动功能损伤负相关。
核心结论
- 高SWV与卒中后上肢高痉挛和功能差相关,提示可能作为疾病进展和治疗随访的可靠定量指标。
研究设计与样本
- 采用声辐射力脉冲剪切波速度检测,在21名对照者和31例近期卒中患者的肱二头肌于90°和0°屈肘时测量SWV,并评估组内与组间信度。
关键影像表现/征象
- 21名对照者优势侧与非优势侧SWV在0°屈肘(p=0.311)和90°屈肘(p=0.436)均无显著差异。
- 31例近期卒中患者瘫痪侧SWV在90°屈肘为2.23±0.15 m/s,高于非瘫痪侧的1.88±0.08 m/s(p=0.036)。
- 瘫痪侧SWV在0°屈肘为3.28±0.11 m/s,高于非瘫痪侧的2.93±0.06 m/s(p=0.002)。
- 90°屈肘时瘫痪侧SWV与改良Ashworth量表及改良Tardieu量表正相关,与卒中康复运动评估评分负相关。
诊断标准与关键数值
- SWV测量的组内和组间信度组内相关系数均归类为优。
临床应用与阅片要点
- 测量肱二头肌SWV时需在90°和0°屈肘两个角度分别评估,瘫痪侧在两个角度均高于非瘫痪侧。
- 患者及对照者手臂和前臂的外观使评估者无法对瘫痪侧或非瘫痪侧设盲。
局限性
- 患者及对照者手臂和前臂的外观使评估者无法对瘫痪侧或非瘫痪侧设盲。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Current clinical evaluations of post-stroke upper limb spasticity are subjective and qualitative. We proposed a quantitative measurement of post-stroke spastic muscle stiffness by using shear-wave ultrasound elastography and tested its reliability. Acoustic radiation force impulse with shear wave velocity (SWV) detection was used to evaluate stiffness of the biceps brachii muscles at 90° and 0° elbow flexion. In 21 control subjects, SWV did not significantly differ between dominant and non-dominant sides at either flexion angle (0°: p = 0.311, 90°: p = 0.436). In 31 patients who had recent stroke, SWV was significantly greater on the paretic side than on the non-paretic side at both 90° (2.23 ± 0.15 m/s vs. 1.88 ± 0.08 m/s, p = 0.036) and 0° (3.28 ± 0.11 m/s vs. 2.93 ± 0.06 m/s, p = 0.002). The physical appearance of arms and forearms of our patients and controls prevented blinding of the rater to paretic or non-paretic side. At 90°, SWV on the paretic side correlated positively with modified Ashworth scale and modified Tardieu scale (spasticity severity) and negatively with Stroke Rehabilitation Assessment of Movement score (motor function impairment). The intra-class correlation coefficients of intra-rater and inter-rater reliability for SWV measurements were classified as excellent. In conclusion, high SWV was associated with high spasticity and poor function of the post-stroke upper limb, suggesting possible use as a reliable quantitative measure for disease progression and treatment follow-up.
引用
- Wu CH, Ho YC, Hsiao MY, et al. Evaluation of Post-Stroke Spastic Muscle Stiffness Using Shear Wave Ultrasound Elastography. Ultrasound Med Biol. 2017. PMID: 28285729. doi:10.1016/j.ultrasmedbio.2016.12.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。