文献速递技术与安全神经介入CT

创伤转诊患者中重复CT扫描:适应证、辐射剂量与费用分析

Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs.
PubMed 文献 · Eur J Radiol · 2017-01-06

这项回顾性研究分析了2014年转诊至一级创伤中心的成人创伤患者,298例中85例(28.5%)为转诊患者,其中74例(87%)在本中心接受了重复CT。重复CT的主要适应证为CT数据传输不充分(39%)、头部CT重复并完成全身CT(32.5%)及已知损伤随访(28.5%)。

要点

  • 转诊创伤患者中87%在本中心接受重复CT,最常见原因为CT数据传输不充分(39%)。

核心结论

  • 相当数量的转诊创伤患者接受了潜在可预防的重复CT,增加了患者辐射剂量和医疗系统费用。

研究设计与样本

  • 回顾性研究,纳入2014年全年从其他医院转诊至一级创伤中心的全部成人创伤患者,共298例中85例转诊,重复CT适应证分为四类,辐射剂量按DLP确定,费用按全国收费表计算。

诊断标准与关键数值

  • 重复CT适应证分类:CT图像数据传输不充分(29/74,39%)、头部损伤后重复头部CT并完成全身CT(24/74,32.5%)、已知损伤随访(21/74,28.5%)、图像质量差(0例)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT.

METHODS: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule.

RESULTS: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n=45,53%) and major body trauma (n=23;27%) not manageable in the referring hospital, repatriation from a foreign country (n=14;16.5%), and no ICU-capacity (n=3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n=29;39%), repetition of head CT with completion to WBCT (n=24;32.5%), and follow-up of known injury (n=21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81'304mGy*cm) and 35'233€, respectively.

CONCLUSION: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hinzpeter R, Sprengel K, Wanner GA, et al. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs. Eur J Radiol. 2017. PMID: 28189198. doi:10.1016/j.ejrad.2017.01.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。