儿童和青少年股骨与胫骨扭转测量:MRI与基于低剂量双平面X线片的3D模型的比较
研究纳入60例儿童(平均年龄10.1岁),由两名读者在轴位MR图像上测量股骨扭转(FT)和胫骨扭转(TT),并与两名独立读者基于双平面X线片(BPR)3D模型的测量比较。MR与BPR-3D模型FT测量的组间一致性ICC为0.95,TT为0.86;TT两种方法测量值存在差异,但差异程度与CT和BPR之间的测量变异相当。
要点
- MR与BPR-3D模型测量股骨扭转的一致性高(ICC 0.95),两者可比。
- 胫骨扭转两方法间一致性较低(ICC 0.86),测量值存在差异。
- 胫骨扭转的差异程度与文献中CT与BPR之间的测量变异相当。
核心结论
- MR图像上股骨扭转测量与BPR-3D模型测量可比;胫骨扭转测量在两种检查方式间存在差异,但差异程度与CT和BPR之间的测量变异相当。
研究设计与样本
- 在60例儿童(平均年龄10.1岁,范围6.2-16.2岁,28例女性)中,由两名读者在轴位MR图像上测量FT和TT,并与两名独立读者基于低剂量双平面X线片(BPR)3D模型的测量进行比较;采用描述性统计、组内相关系数(ICC)和Bland-Altman分析评估读者间和方法间一致性。
关键影像表现/征象
- MR图像上FT范围为-8.4°至54.1°,TT范围为0°至45.9°。
- BPR-3D模型上FT范围为-13°至63°,TT范围为4°至52°。
- 两种方法间FT差值中位数为-0.18°(范围-13.6°至19.1°),TT差值中位数为-0.20°(范围-18.4°至9.5°)。
诊断标准与关键数值
- 读者间一致性ICC:MR图像上FT为0.98、TT为0.96;BPR-3D模型上FT为0.98、TT为0.94。
- 方法间一致性ICC:FT为0.95(95%CI 0.93-0.96),TT为0.86(95%CI 0.24-0.95)。
- MR读者间平均差异:FT为3.1°(范围0.0°-8.0°),TT为3.2°(范围0.1°-9.5°)。
- Bland-Altman分析中,除FT的5次测量和TT的6次测量外,所有测量均在95%一致性界限内(FT:-10.8°至11.5°;TT:-14.6°至4.2°)。
临床应用与阅片要点
- 在儿童股骨扭转评估中,MR测量与BPR-3D模型测量具有可比性,可作为替代方法。
- 胫骨扭转的MR与BPR-3D模型测量值存在差异,报告时需注意检查方式对结果的影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of our study was to evaluate the reliability and interchangeability of femoral (FT) and tibial torsion (TT) measurements in children using magnetic resonance (MR) imaging compared to measurements on 3D models based on biplanar radiographs (BPR).
MATERIALS AND METHODS: FT and TT were measured in 60 children (mean age 10.1 years; range 6.2-16.2 years; 28 female) using axial MR images by two readers. MR measurements were compared to measurements based on BPR-3D models by two separate independent readers. Interreader and intermethod agreements were calculated using descriptive statistics, the intraclass correlation coefficient (ICC), and Bland-Altman analysis.
RESULTS: FT/TT was -8.4°-54.1°/0°-45.9° on MR images and -13°-63°/4°-52° for measurements on BPR-3D models. The median of difference between the two methods was -0.18° (range -13.6°-19.1°) for FT and -0.20° (range -18.4°-9.5°) for TT, respectively. Interreader agreement (ICC) of FT/TT measurements was 0.98/0.96 on MR images and 0.98/0.94 on BPR 3D models. Intermethod agreement (ICC) for MR measurements was 0.95 [95% confidence interval (CI), 0.93-0.96] for FT and of 0.86 (CI, 0.24-0.95) for TT. Mean interreader differences at MR were 3.1° (0.0°-8.0°) for FT and 3.2° (0.1°-9.5°) for TT. On Bland-Altman plots all measurements were within the 95% limit of agreement (-10.8°; 11.5° for FT; -14.6°; 4.2°) for TT-except for five measurements of FT and six measurements of TT.
CONCLUSION: FT measurements on MR images are comparable to measurements using BPR-3D models. TT measurements differ between the two modalities, but the discrepancy is comparable to measurement variations between CT and BPR.
引用
- Rosskopf AB, Buck FM, Pfirrmann CW, et al. Femoral and tibial torsion measurements in children and adolescents: comparison of MRI and 3D models based on low-dose biplanar radiographs. Skeletal Radiol. 2017. PMID: 28154901. doi:10.1007/s00256-017-2569-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。