低剂量CT用于颅缝早闭:在大幅降低辐射剂量的同时保留诊断价值

Low-Dose CT for Craniosynostosis: Preserving Diagnostic Benefit with Substantial Radiation Dose Reduction.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-02-09

研究对33例疑似颅缝早闭患儿的头部CT投影数据进行模拟低剂量重建(25%、10%、2%剂量),3名神经放射科医生盲法随机独立判读。常规剂量下多阅片者品质因数均值为0.92,2%剂量下为0.86;25%和10%剂量与常规剂量的品质因数差值95%CI包含0,提示性能相似或非劣。结论为剂量降低75%-90%可不损害观察者性能。

要点

  • 模拟25%和10%剂量时,品质因数与常规剂量的差值95%CI包含0,提示观察者性能相似或非劣。
  • 2%剂量下多阅片者品质因数均值降至0.86(95%CI 0.79-0.94),仍保持较高诊断性能。
  • 常规剂量容积CT剂量指数均值为15.5±2.3 mGy(范围9.69-19.38 mGy)。

核心结论

  • 对于儿童颅缝早闭评估的头部CT,剂量降低75%-90%不会损害观察者性能。

研究设计与样本

  • 对疑似颅缝早闭患儿头部CT投影数据进行存档,用经验证方法模拟25%、10%、2%应用剂量的低剂量图像;3名神经放射科医生盲法随机独立判读;参考标准由阅片者基于常规剂量2D和3D图像判读一致性定义。

诊断标准与关键数值

  • 共33例患儿,21例有颅缝早闭(39条阳性骨缝和225条阴性骨缝);常规剂量容积CT剂量指数均值15.5±2.3 mGy(范围9.69-19.38 mGy);仅用3D图像时多阅片者品质因数均值从常规剂量的0.92(95%CI 0.90-0.95)降至2%剂量的0.86(95%CI 0.79-0.94);2D和3D联合时合并阅片者品质因数从常规剂量的0.91(95%CI 0.89-0.95)降至2%剂量的0.85(95%CI 0.76-0.95);25%和10%剂量与常规剂量的品质因数差值95%CI包含0,提示性能相似或非劣。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Given the positive impact of early intervention for craniosynostosis, CT is often performed for evaluation but radiation dosage remains a concern. We evaluated the potential for substantial radiation dose reduction in pediatric patients with suspected craniosynostosis.

MATERIALS AND METHODS: CT projection data from pediatric patients undergoing head CT for suspected craniosynostosis were archived. Simulated lower-dose CT images corresponding to 25%, 10%, and 2% of the applied dose were created using a validated method. Three neuroradiologists independently interpreted images in a blinded, randomized fashion. All sutures were evaluated by using 3D volume-rendered images alone, and subsequently with 2D and 3D images together. Reference standards were defined by reader agreement by using routine dose and 2D and 3D images. Performance figures of merit were calculated based on reader response and confidence.

RESULTS: Of 33 pediatric patients, 21 had craniosynostosis (39 positive sutures and 225 negative sutures). The mean volume CT dose index was 15.5 ± 2.3 mGy (range, 9.69-19.38 mGy) for the routine dose examination. Average figures of merit for multireader analysis ranged from 0.92 (95% CI, 0.90-0.95) at routine pediatric dose to 0.86 (95% CI, 0.79-0.94) at 2% dose using 3D images alone. Similarly, pooled reader figures of merit ranged from 0.91 (95% CI, 0.89-0.95) at routine pediatric dose to 0.85 (95% CI, 0.76-0.95) at 2% dose using 2D and 3D images together. At 25% and 10% dose, 95% CI of the difference in figures of merit from routine dose included 0, suggesting similar or noninferior performance.

CONCLUSIONS: For pediatric head CT for evaluation of craniosynostosis, dose reductions of 75%-90% were possible without compromising observer performance.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Montoya JC, Eckel LJ, DeLone DR, et al. Low-Dose CT for Craniosynostosis: Preserving Diagnostic Benefit with Substantial Radiation Dose Reduction. AJNR Am J Neuroradiol. 2017. PMID: 28183836. doi:10.3174/ajnr.A5063